Installation and operation manual9 FXSQ20~140P7VEBVRV System air conditioners4PW56483-1External static pressure settingsSettings for external static pressure can be achieved in 2 ways:Using the airflow automatic adjustment functionAirflow automatic adjustment is the volume of blow-off air thathas been automatically adjusted to the rated quantity.1 Make sure the test run is done with a dry coil.If the coil is not dry, run the unit for 2 hours with fan only to drythe coil.2 Check if the power supply wiring to the air conditioning unit iscompleted along with the duct installation.If a closing damper is installed in the air conditioning unit, makesure that it is open.Also check if the air filter is properly attached into the airpassage on the air suction side of the air conditioning unit.3 If there is more than one air inlet and outlet, adjust the dampersso that the airflow rate of each air inlet and outlet is conform withthe designed airflow rate.Make sure the air conditioning unit is in fan operation mode.Press and set the airflow adjustment button on the remotecontroller to change the airflow rate to H or L.4 Setting the airflow automatic adjustment settings.When the air conditioning unit is running in fan operation modeperform the next steps:- stop the air conditioning unit,- go to field setting mode,- select mode No. 21 (or 11 in case of group setting),- set the first code No. to "7",- set the second code No. to "03".Return to normal operating mode after setting these settingsand press the ON/OFF operation button. The operation lamp willlight up and the air conditioning unit will start the fan operationfor airflow automatic adjustment.After 1 to 8 minutes, the air conditioning unit stops operatingautomatically when the fan operation for airflow automaticadjustment has been carried out, the operation lamp will be off.5 When the air conditioning unit has stopped, check on an indoorunit if the second code No. of mode No. 21 is set to "02".If the air conditioning unit does not stop operating or the secondcode No. is not "02", repeat step 4.If the outdoor unit is not turned on, the display on the remotecontroller will show "U4" or "UH" (refer to "Test operation" onpage 10). However, you can continue setting this functionbecause these messages are only applicable to outdoor units.After setting this function, be sure to turn on the outdoor unitbefore performing the test operation on the outdoor unit.If any other error display occurs on the display of the remotecontroller, refer to "Test operation" on page 10 and the operationmanual of the outdoor unit. Check the defective point.Using the remote controllerCheck on an indoor unit if the second code of mode No. 21 is set to"01" (= factory setting). Change the second code according to theexternal static pressure of the duct to be connected as shown intable 2.Table 2Control by 2 Remote Controllers (Controlling 1 indoorunit by 2 remote controllers)When using 2 remote controllers, one must be set to "MAIN" and theother to "SUB".MAIN/SUB CHANGEOVER■ Insert a wedge-head screwdriver into the recess between theupper and lower part of the remote controller and, working fromthe 2 positions, pry off the upper part. (See figure 18)(The remote controller PC board is attached to the upper part ofthe remote controller.)■ Turn the main/sub changeover switch on one of the two remotecontroller PC boards to "S". (See figure 19)(Leave the switch of the other remote controller set to "M".)Do not adjust the dampers during fan operation forairflow automatic adjustment.ModeNo.Firstcode No.Secondcode No. Setting content11 (21) 701 Airflow adjustment is OFF02 Completion of airflow adjustment03 Start of airflow adjustment■ If the external static pressure of the FXSQ140P7VEBis higher than 100 Pa, do not use airflow automaticadjustment function.■ If there is no change after airflow adjustment in theventilation paths, be sure to perform setting the airflowautomatic adjustment again.■ Contact your dealer if there is no change afterperforming airflow adjustment in the ventilation paths,after performing the test operation of the outdoor unitor when the air conditioning unit is moved to anotherlocation.■ If booster fans, an outdoor air processing unit or HRVvia duct are used, do not use airflow automaticadjustment control with a remote controller.■ If the ventilation paths have been changed, performthe setting of the airflow automatic adjustment againas described above from step 3 onwards.NOTE The second code No. is set to "03" by default.ModeNo.FirstcodeNo.SecondcodeNo.External static pressure (Pa)FXSQ20 25 32 40 50 63 80 100 125 14013(23) 603 30 30 30 30 30 30 40 40 50 5004 35 35 35 35 35 40 45 50 55 5505 40 40 40 40 40 50 50 60 60 6006 45 45 45 45 45 60 60 70 70 7007 50 50 50 50 50 70 70 80 80 8008 55 55 55 60 60 80 80 90 90 9009 60 60 60 70 70 90 90 100 100 10010 65 65 65 80 80 100 100 110 110 11011 70 70 70 90 90 — — 120 120 12012 — — — 100 100 — — — — 13013 — — — — — — — — — 1401 Remote controller PC board2 Factory setting3 Only one remote controller needs to be changed |
Related manuals for Daikin FXSQ140P7VEB
Daikin FXSQ15A2VEB Installation And Operation Manual
Daikin FXSQ15A2VEB Installation And Operation Manual
Daikin FXLQ20P7VEB Installation And Operation Manual
Daikin FXSN71A2VEB Installation And Operation Manual
Daikin FXSN50A2VEB Installation And Operation Manual
Daikin FXSA15A2VEB Installation And Operation Manual
Daikin FXFQ20AVEB Installation And Operation Manual
Daikin FXFQ20BVEB Installation And Operation Manual
Daikin FXUA50AVEB Installation And Operation Manual
Daikin FXHA32AVEB Installation And Operation Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine