71-3 Standard supplied accessories∗ Use the flare nut attached to the discharge gas stop valve for the “dis-charge gas line piping attached to unit” (1).(Refer to figure 21)1. Operation manualInstallation manualClamp2. Attached pipe1-4 Option accessoryTo install the outdoor unit, the following optional parts are also required.• Refrigerant branching kit (For R410A only: Always use anappropriate kit dedicated for your system.)for 3 pipesfor 2 pipes• Outdoor unit multi connection piping kit (For R410A only:Always use an appropriate kit dedicated for your system.)∗ To select an optimum refrigerant branching kit, refer to“6. Refrigerant Piping”.1-5 Technical specifications (1)(1) Refer to the engineering data book for the complete list of specifications.(2) The nominal cooling capacity is based on: - indoor temperature: 80°FDB / 67°FWB- outdoor temperature: 95°FDB- pipe length: 25ft.- level difference: 0ft.(3) The nominal heating capacity is based on: - indoor temperature: 70°FDB- outdoor temperature: 47°FDB / 43°FWB- pipe length: 25ft.- level difference: 0ft.(4) The nominal input includes total input of the unit: compressor, fan motor and con-trol circuit.1-6 Electrical specifications (1)2. MAIN COMPONENTSFor main components and function of the main components, refer to theEngineering Data Book.3. SELECTION OF LOCATIONThis unit, both indoor and outdoor, is suitable for installation in a com-mercial and light industrial environment. If installed as a householdappliance it could cause electromagnetic interference.The VRV OUTDOOR units should be installed in a location that meetsthe following requirements:1. The foundation is strong enough to support the weight of the unit andthe floor is flat to prevent vibration and noise generation.Name Clamp (1) Clamp (2) Clamp (3)Suction gas linepiping attached tounit (1)Quantity 9 pcs. 2 pcs. 1 pc. 1 pc.ShapeNameSuction gas linepiping attached to unit(2)Suction gas linepiping attached tounit (3)Discharge gas linepiping attached tounit (1) ∗Quantity 1 pc. 1 pc. 1 pc.ShapeNameDischarge gasline pipingattached to unit(2)Discharge gasline pipingattached to unit(3)Vinyl tube OthersQuantity 1 pc. 1 pc. 1 pc. • Operationmanual• Installationmanual• AdditionalrefrigerantchargelabelShapeREFNET header - KHRP25M33H KHRP25M72HREFNET joint KHRP25M22T KHRP25M33T KHRP25M72TUREFNET header KHRP26M22H KHRP26M33H KHRP26M72HREFNET joint KHRP26M22T KHRP26M33T KHRP26M72TUNumber of outdoor units connected 2 unitsKit name BHFP26M90USmall LargeGeneral REYQ96MTJU REYQ192MTJUNominal cooling capacity(2) (MBh) 96 192Nominal heating capacity(3) (MBh) 108 216Nominal input cooling /heating (4) (kW) 8.67 / 9.19 17.34 / 18.38Dimensions H×W×D (inch) 64 × 48-7/8 × 30-1/8 (64 × 48-7/8 × 30-1/8) +(64 × 48-7/8 × 30-1/8)Mass (Ib.) 650 650+650ConnectionsRefrigerant suction gas pipe (inch) 7/8 1-1/8Refrigerant discharge gaspipe (inch) 3/4 7/8Refrigerant liquid pipe (inch) 3/8 5/8Compressor REYQ96MTJU REYQ192MTJUOil type - Synthetic(ether)oil Synthetic(ether)oilOil charge volume (I) 1.9+1.6 (1.9+1.6)+(1.9+1.6)Crankcase heater (W) 33+33 (33+33)+(33+33)Refrigerant type - R410A R410ARefrigerant charge (Ib.) 27.3 27.3+27.3Condenser REYQ96MTJU REYQ192MTJUNominal air flow (CFM) 7400 7400+7400Fan motor output (W) 750 750+750Model REYQ96MTJU REYQ192MTJUPower supplyPhase - 3~ 3~Frequency (Hz) 60 60Voltage (V) 208-230 208-230Voltage torerance (%) ±10 ±10Recommended fuses (A) 70 70+70CompressorPhase - 3~ 3~Frequency (Hz) 60 60Voltage (V) 208-230 208-230Nominal running current (A) 10.1+13.1 (10.1+13.1)+(10.1+13.1)Model REYQ96MTJU REYQ192MTJUControl and fan motorTypeVoltage (V) 208-230 208-230Nominal running current (A) 4.5 4.5+4.5