Outdoor Unit SiBE01-82998 Removal Procedure2.4 Removal of CompressorProcedure Warning Be sure to wait 10 minutes or more after turning off all power suppliesbefore disassembling work.Step Procedure Points1. Remove the compressor.1 Unscrew the nut (M13)of the compressor. Before working,make sure that therefrigerant is emptyin the circuit. Be sure to applynitrogenreplacement whenheating up thebrazed part.WarningVentilate when refrigerantleaks during the work.(If refrigerant contacts fire, itwill cause to arise toxic gas.) Provide a protective sheet ora steel plate so that thebrazing flame cannotinfluence peripheries. Be careful so as not to burnthe compressor terminals orthe name plate. Be careful so as not to burnthe heat exchanger fin.WarningSince it may happen thatrefrigeration oil in thecompressor will catch fire,prepare wet cloth so as toextinguish fire immediately.In case of the difficulty withgas brazing machine1. Disconnect the brazed partwhere is easy to disconnectand restore.2. Cut pipes on the main unit bya miniature copper tubecutter in order to make iteasy to disconnect.2 Heat up the brazed partof the discharge sideand disconnect.(R8559)(R8560)