Si281314E Procedure to Remove PCB Assy (1)Removal Procedure 54. Procedure to Remove PCB Assy (1)Procedure Warning Be sure to wait for 10 minutes or more after turning off all powersupplies before disassembling work.Step Procedure Points Remove the top panel,the front panel 2, the sidepanel, and the pipingcover, following theprocedure indicated at"Removing OutsidePanels and RelatedParts". Remove the switch box,following the procedureindicated at "Removingswitch box".1. Remove the PCB for thedisplay (A2P)1 Remove theconnectors (X205A)on the PCB for thedisplay. Since the PCB forthe display (A2P) isfixed with 2 hooks,take from them andthen remove thePCB for the display.PCB for the display (Retrieved) Installation section of thePCB for the display (A2P)PCB for the displayOutdoor unitPCBHooksConnector(X205A)Hook PCBResin case