• Outdoor Unit • • RZQG-L7V1/LY112• Split - Sky Air • Outdoor Unit82 SpecificationsNotes(1) PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC(2) Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current \> 16A and ≤ 75A per phase(3) Short-circuit power(4) See separate drawing for electrical data(5) 3 with re-chargingPiping connections Liquid Quantity 1Type Flare connectionOD mm 9.52Gas Quantity 1Type Flare connectionOD mm 15.9Drain Quantity 5Type HoleID mm -OD mm 26Piping length OU - IU Min. m 5 (5) 5 (2)Max. m 50 75 50 75System Equivalentm 70 90 70 90Chargelessm 30Additional refrigerant charge kg/m See installation manual 4P302555-1Level difference IU - OU Max. m 30.0IU - IU Max. m 0.5Heat insulation Both liquid and gas pipesDefrost method Pressure equalisingDefrost control Sensor for outdoor heat exchanger temperatureSafety devices Item 01 High pressure switch02 Fan motor thermal protection03 Fuse2-3 Electrical Specifications RZQG71L7V1RZQG100L7V1RZQG125L7V1RZQG140L7V1RZQG71LY1RZQG100LY1RZQG125LY1RZQG140LY1Power supply Name V1 Y1Phase 1~ 3N~Frequency Hz 50Voltage V 220-240 380-415Voltage range Min. % 10Max. % 10Current Zmax List Complies to EN61000-3-11Recommended fuses A 25 40 16 20 25Current - 50Hz Maximum fuse amps (MFA) A 20 32 16 20Current - 60Hz Maximum fuse amps (MFA) A -Wiring connections For power supply Remark See installation manual 4P302555-1For connection withindoorRemark See installation manual 4P302555-1Power supply intake Outdoor unit only2-2 Technical Specifications RZQG71L7V1RZQG100L7V1RZQG125L7V1RZQG140L7V1RZQG71LY1RZQG100LY1RZQG125LY1RZQG140LY1