- safety cautions
- Part 1 List of Functions
- Functions
- Cooling Only - Outdoor Unit
- Heat Pump - Indoor Unit
- Heat Pump - Outdoor Unit
- Part 2 Specifications
- Specifications
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Indoor Unit
- Floor Standing Type
- Floor / Ceiling Suspended Dual Type
- Duct Connected Type
- Ceiling Mounted Cassette Type
- Ceiling Mounted Built-in Type
- Ceiling Suspended Type
- Remote Controller
- Wireless Remote Controller
- Outdoor Unit
- Part 4 Function and Control
- Function of Indoor Unit (RA Models)
- Operation Starting Control
- Airflow Direction Control
- Fan Speed Control for Indoor Units
- Program Dry Operation
- Automatic Operation
- Thermostat Control
- NIGHT SET Mode
- ECONO Operation
- HOME LEAVE Operation
- Area INTELLIGENT EYE Operation
- INTELLIGENT EYE Operation
- Inverter POWERFUL Operation
- Other Functions
- Function of Indoor Unit (SA Models)
- Thermostat Sensor in Remote Controller
- Freeze Prevention Control
- Hot Start Control (In Heating Operation Only)
- Function of Thermistor
- Control Specification
- Frequency Control
- Controls at Mode Changing / Start-up
- Discharge Pipe Temperature Control
- Input Current Control
- Heating Peak-cut Control
- Liquid Compression Protection Function
- Low Hz High Pressure Limit
- pressure equalizing control
- Malfunctions
- Part 5 Operation Manual
- System Configuration
- RA Indoor Unit
- name of parts
- fan operation
- operating conditions
- FTXS, FVXS Series - ARC452A1, A3
- names of parts
- opening the front panel
- ATXS, FLK(X)S, FDK(X)S Series - ARC433B67, B68, B69, B76
- SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
- BRC1E51A7
- operation mode
- program dry
- key lock
- airflow direction
- ventilation mode
- schedule timer
- holiday setting
- convenient functions
- clock setting
- useful information
- BRC7E530W/531W, BRC7F532F/533F, BRC7EA63W/66
- operation range
- operation procedure
- Part 6 Service Diagnosis
- Troubleshooting with LED
- Problem Symptoms and Measures
- Service Check Function
- Code Indication on Remote Controller
- Troubleshooting for RA Indoor Unit - F(C)TXG FTXS, ATXS, FVXS, FLK(X)S, FDK(X)S Series
- Freeze-up Protection Control or Heating Peak-cut Control
- Fan Motor or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Front Panel Open / Close Fault (FTXG and CTXG Series)
- Signal Transmission Error (between Indoor Unit and Outdoor Unit)
- Unspecified Voltage (between Indoor Unit and Outdoor Unit)
- Troubleshooting for SA Indoor Unit - FFQ, FCQ FDBQ, FBQ, FHQ Series
- Drain Water Level System Abnormality
- Swing Motor Lock (FHQ Series)
- Drain System Abnormality
- Thermistor or Related Abnormality
- Remote Controller Thermistor Abnormality
- Field Setting Abnormality
- Troubleshooting for Outdoor Unit
- Outdoor Unit PCB Abnormality
- OL Activation (Compressor Overload)
- Compressor Lock
- dc fan lock
- Input Overcurrent Detection
- High Pressure Control in Cooling
- Compressor Sensor System Abnormality
- Position Sensor Abnormality
- CT or Related Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- Electrical Box Temperature Rise
- Radiation Fin Temperature Rise
- Output Overcurrent Detection
- Refrigerant Shortage
- Low-voltage Detection or Over-voltage Detection
- Signal Transmission Error (on Outdoor Unit PCB)
- Check
- Fan Motor Connector Check
- Electronic Expansion Valve Check
- Four Way Valve Performance Check
- Inverter Checker" Check
- Rotation Pulse Check on the Outdoor Unit PCB
- Installation Condition Check
- Outdoor Fan System Check
- Part 7 Removal Procedure
- Outdoor Unit - 50~75 Class
- Removal of Electrical Box
- Removal of PCBs
- Removal of Outdoor Fan / Fan Motor
- Removal of Sound Blankets
- Removal of Coils / Thermistors
- Removal of Distributor
- Removal of Four Way Valve
- Removal of Compressor
- Outdoor Unit - 80/90 Class
- Removal of Fan Motor
- Part 8 Trial Operation and Field Settings
- Pump Down Operation
- Forced Operation
- Wiring Error Check Function
- Trial Operation
- Field Settings
- jumper and switch settings
- Application of Silicon Grease to a Power Transistor and a Diode Bridge
- Part 9 Appendix
- Piping Diagrams
- Wiring Diagrams
|
SiBE121021_C Field SettingsTrial Operation and Field Settings 4475. Field Settings5.1 RA Indoor Unit - F(C)TXG, FTXS, ATXS, FVXS, FLK(X)S,FDK(X)S Series5.1.1 Model Type Setting This remote controller is common to the heat pump model and cooling only model. Use theDIP switch on the remote controller to set the heat pump model or cooling only model. Make the setting as shown in the illustration. (The factory set is the heat pump side.)• Heat pump model: Set the DIP switch to H/P.• Cooling only model: Set the DIP switch to C/O.5.1.2 When 2 Units are Installed in 1 RoomOutline When 2 indoor units are installed in 1 room, 1 of the 2 pairs of indoor unit and wireless remotecontroller can be set for different address.Both the indoor unit PCB and the wireless remote controller need alteration.Indoor Unit PCB (1) Remove the front grille.(2) Remove the electrical box.(3) Remove the shield plate of the electrical box.(4) Cut the address setting jumper JA on the PCB.H/P C/ODIP switch(R12755)FTXG and CTXG Series FTXS and ATXS Series 20-50 Class(Bottom of electrical box)(R12036)ADDRESS : JAEXIST : 1CUT : 2JAADDRESSJAADDRESSJA(R12216)EXISTCUT12