4TM-RHR-1214-A3. SpecificationsRHR10CV1 RHR15CV1WALL MOUNTED Btu/h 10,000 13,000CEILING CASSETTE Btu/h 10,00010,00013,000CEILING EXPOSED-CBCEILING EXPOSED-ECEILING CONCEALEDBtu/hBtu/hBtu/h--13,00012,00013,000V/Ph/HzCOMPRESSOR TYPERUNNING CURRENT A 3.5 5.4LOCKED ROTOR CURRENT A 20 25INPUT POWER W 817 1218PROTECTION DEVICEPOWER SOURCE V/Ph/HzFAN TYPE / DRIVEBLADE MATERIALAIR FLOW cmm/cfm 740 900DIAMETER mm/inA 0.21 0.25W 48 56MOTOR SPEED RPM 790 900MATERIALROW / FIN PER INCH 1 / 14 2 / 16FACE AREA m²/ft² 0.328 / 3.50 0.312 / 3.36HEIGHT mmWIDTH mmDEPTH mmWEIGHT kgSOUND PRESSURE LEVEL dBA 48 50MATERIALTYPELIQUID mm/inGASWATERmm/inmm/in9.52 / 3/8 12.7 / 1/2355 / 146.35 / 1/49.52 / 3/854070025029R 22 / CAPILLARY TUBE (OUTDOOR)INDUCTION MOTORSEAMLESS INNER GROOVE COOPERALUMINIUM (SLIT FIN)GALVANISED MILD STEELFLARE220-240 / 1 / 50ROTARY220-240 / 1 / 50OVERLOAD PROTECTIONPROPELLER / DIRECTGLASS REINFORCED ACRYL STYRENE RESINCOMPRESSOR POWER SOURCEFANTUBE MATERIALOUTDOOR UNIT MODELTOTAL COOLING CAPACITY(DEPENDING ON INDOOR UNIT)INPUT POWERREFRIGERANT TYPE & CONTROLDIMENSIONCASINGSIZERUNNING CURRENTMOTOR TYPEFINOUTDOOR UNITPIPE COIL1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO AHRI 210/240.3) NOMINAL COOLING CAPACITY IS BASED ON THE FOLLOWING CONDITION: OUTDOOR -35˚C, INDOOR -27˚C DB / 19˚C WB.4) WINTERSPA MUST USE GOVERNMENT TAP WATER FOR WATER USAGE, OTHERWISE THE WARRANTY WILL BE VOIDED.Specification (R22)WinterSpa - RHR-C Series