Output SpecificationsThe BOA2 vision system provides three (3) dedicated opto-isolated, solid state relayoutputs and a separate dedicated light strobe (pin 2 of lamp connector).Specification DefinitionVoltage (Vin) Load 30V maximum (lamp voltage = Vin-0.56V)Current GPO[0:2] 200 mA max @ 20°C (drives to OCMN when active)STRB 200 mA max (drives to Vin-1V when active)NOTE: Strobe timing selected in iNspect Express Sensor PanelProtection Fuse PTC fuses to 200 mA at 20°C or 150 mA at 70°CCommon pin Out PWR or GNDSwitch Time ON 400 MicrosecondsOFF 80 MicrosecondsThe active polarity of each output is configured in the iNspect Express application asdetailed on the following page.To connect with an NPN input source, connect the camera output (pin 3, 10 or 11) to theNPN source input and the camera common output (pin 4) to GND. When the cameraoutput turns ON, the opto switch closes and OUTX = 0 (current flows through load).To connect with an PNP input source, connect the camera output (pin 3, 10 or 11) to thePNP source input and the camera common output (pin 4) to PWR. When the cameraoutput turns ON, the opto switch closes and OUTX = output common.Output DiagramVersion 4.3; 2017-11-2030BOA2-XA Installation