1M60 Camera User’s Manual 18DALSA C32-10010-013.3 Reading the Camera TypeThis read command returns an 8-bit value unique to the type of camera interrogated.A 1M60 will return a value of 02h when this command is issued. This is useful forapplications that need to function with multiple DALSTAR camera types.Example: Read the camera typeCommand Value Returned (1M60)Binary 1100 0011 0000 0010Hex C3h 02h3.4 Reading the Firmware RevisionThis command returns a byte in which the lower nibble is the revision number for theclock board firmware and the upper nibble is undefined. The ability to read thisvalue may assist in customer support issues.Example: Read the firmware versionCommandBinary 1100 0101Hex C5h3.5 Resetting the CameraThis is the only “write” command that is not followed by a data byte. This commandresets all clock board registers to their default values (the values used at power-up).Table 13. Default values in effect after resetFeature 1M60 DefaultFrame Rate (fps) 60Integration Time (ms) 15.8Resolution (pixels) 1024 x 1024Video Gain 1xBinning Mode 1x1Pixel Offset 0Triggering INTERNALIntegration Control INTERNALData Rate (MHz) 20ExampleUse this command to reset the camera:Command ValueBinary 1000 0000 -Hex 80h -