4Clean Before UsingAfter you remove all of the packaging materials, clean the inside ofyour freezer before using it. See the cleaning instructions in“Freezer Care.”Location RequirementsIMPORTANT: Do not install the freezer near an oven, radiator, orother heat source, nor in a location where the temperature will fallbelow 40°F (5°C).Check the strength of the floor before installing your freezer. Itshould hold the weight of a freezer fully loaded with food.Allow at least 3" (7.5 cm) of air space at the top and on both sidesof the freezer and 1" (2.5 cm) between the back of the freezer andthe wall. If the freezer is to be against a wall, leave extra space onthe hinge side so the door can open wider.NOTE: This freezer may be installed side by side with anotherrefrigerator or freezer. Allow for a 3" (7.5 cm) clearance at the topand sides and a ¹⁄₄" (0.64 cm) clearance between the appliances.Electrical RequirementsBefore you move your freezer into its final location, it is importantto make sure you have the proper electrical connection.Recommended grounding methodA 115 volt, 60 Hz., AC only, 15- or 20-amp fused, groundedelectrical supply is required. It is recommended that a separatecircuit serving only your freezer be provided. Use an outlet thatcannot be turned off by a switch. Do not use an extension cord.NOTE: Before performing any type of installation, cleaning, orremoving a light bulb, turn the Temperature Control to the OFFposition as shown and then disconnect the freezer from theelectrical source.Important information to know about glass shelvesand covers:Do not clean glass shelves or covers with warm water whenthey are cold. Shelves and covers may break if exposed tosudden temperature changes or impact, such as bumping.Tempered glass is designed to shatter into many small,pebble-size pieces. This is normal. Glass shelves and coversare heavy. Use both hands when removing them to avoiddropping.WARNINGExplosion HazardKeep flammable materials and vapors, such asgasoline, away from freezer.Failure to do so can result in death, explosion, or fire.3" (7.5 cm)3" (7.5 cm)Electrical Shock HazardPlug into a grounded 3 prong outlet.Do not remove ground prong.Do not use an adapter.Do not use an extension cord.Failure to follow these instructions can result in death,fire, or electrical shock.WARNING