This is the most energy and cost efficient way to set the indoor tempera-ture and should therefore be used for long term temperature settings.42 0 0 -2 02 44 05 6 23151. Supply temperature (°C)2. Maximum setpoint value°3. Outdoor temperature (°C)4. 0°C5. °Set value (standard 40°C)The following parameters can be adjusted:Parameter DescriptionCURVE If the CURVE value is increased, the heat curve will becomesteeper and if the value is reduced, it will become flatter. Raisefor hotter indoor temperature, reduce for lower temperature.MIN Lowest set point for supply temperature.MAX Highest set point for supply temperature.CURVE 5 Used to adjust the heat curve at an outdoor temperature of+5°C.CURVE 0 Used to adjust the heat curve at an outdoor temperature of0°C.CURVE -5 Used to adjust the heat curve at an outdoor temperature of-5°CHEAT STOP This function stops all production of heat when the outdoortemperature is equal to, or higher than, the set heat stop value.Note! High temperatures in an underfloor heating system candamage parquet floors.User manual VUBMA902 – 17