Adjust the following parameters:Par. 1-00 Configuration Mode Speed closed-loop [1]Par. 1-01 Motor Control Principle Flux with feedback [3]Par. 1-10 Motor Construction PM, non-salient SPM [1]Par. 1-24 Motor Current NameplatePar. 1-25 Motor Nominal Speed NameplatePar. 1-26 Motor Cont. Rated Tor-queNameplateAMA is not possible on PM motorsPar. 1-30 Stator Resistance Motor data sheetPar. 1-37 d-axis inductance (Ld) Motor data sheet (mH)Par. 1-39 Motor Poles Motor data sheetPar. 1-40 Back EMF at 1000 RPM Motor data sheetPar. 1-41 Motor Angle Offset Motor data sheet (Usually zero)Par. 17-50 Poles Resolver data sheetPar. 17-51 Input Voltage Resolver data sheetPar. 17-52 Input Frequency Resolver data sheetPar. 17-53 Transformation Ratio Resolver data sheetPar. 17-59 Resolver Interface Enabled [1]8.1.11. Relay Option MCB 105The MCB 105 option includes 3 pieces of SPDT contacts and must be fitted into option slot B.Electrical Data:Max terminal load (AC-1) 1) (Resistive load) 240 V AC 2AMax terminal load (AC-15) 1) (Inductive load @ cosφ 0.4) 240 V AC 0.2 AMax terminal load (DC-1) 1) (Resistive load) 24 V DC 1 AMax terminal load (DC-13) 1) (Inductive load) 24 V DC 0.1 AMin terminal load (DC) 5 V 10 mAMax switching rate at rated load/min load 6 min -1/20 sec-11) IEC 947 part 4 and 5When the relay option kit is ordered separately, the kit includes:• Relay Module MCB 105• Enlarged LCP fixture and enlarged terminal cover• Label for covering access to switches S201, S202 and S801• Cable strips for fastening cables to relay moduleThe relay option does not support FC 302 adjustable frequency drive s manufactured before week50/2004.Min. software version: 2.03 (par. 15-43).FC 300 Design Guide 8. Options and AccessoriesMG.33.B9.22 - VLT® is a registered Danfoss trademark. 1578