Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Introduction
- Safety
- Cautions and Notices
- Product Overview
- Description of the Type Code
- Enclosure Sizes
- Receiving the Delivery
- Accessories Bag, MR6
- Accessories Bag, MR8
- Storing the Product
- Using the Product Modified Label
- Mounting
- Cooling Requirements
- Necessary Quantity of Cooling Air
- Electrical Installation
- UL Standards on Cabling
- Fuse Selection
- EMC-compliant Installation
- Installation in a Corner-grounded Network
- Get Access and Locate the Terminals
- Get Access and Locate the Terminals for MR8
- Get Access and Locate the Terminals for MR9
- Installation of Cables
- Installing the Cables, MR4-MR7
- Installing the Cables, MR8-MR9
- Installation in an IT System
- Installing the AC drive in an IT System, MR7
- Installing the AC drive in an IT System, MR8
- Installing the AC drive in an IT System, MR9
- Installation in a Marine Environment
- Control Unit
- Control Unit Cabling
- DIP Switches on the Control Unit
- Isolation of the Digital Inputs from Ground
- Internal Fieldbuses in VACON® 100 Products
- General Cabling Instructions for Fieldbus
- Strain Relief
- Using Fieldbus through an Ethernet Cable
- Danfoss A/S © 2019.05 AQ298036140958en
- RS485 Commissioning and Cabling
- Grounding the Cable Shield
- The RS485 Bus Biasing
- Available Option Boards
- Option Board Installation
- Battery for the Real-Time Clock (RTC)
- Description of the Control Panel
- Displays of the Control Panel
- Commissioning
- Commissioning the AC Drive
- Insulation Checks of the Motor Cable
- Checking the AC Drive after Commissioning
- Maintenance
- Specifications
- Dimensions for Wall-mounting for MR5
- Dimensions for Wall-mounting for MR6
- Dimensions for Wall-mounting for MR7
- Dimensions for Wall-mounting for MR8
- Dimensions for Wall-mounting for MR9
- Dimensions for Flange-mounting
- Dimensions for Flange-mounting for MR5
- Dimensions for Flange-mounting for MR6
- Dimensions for Flange-mounting for MR7
- Cable and Fuse Sizes, Mains Voltage 208–240 V and 380–500 V
- Cable and Fuse Sizes, Mains Voltage 525–690 V
- Cable and Fuse Sizes, Mains Voltage 208–240 V and 380–500 V, North America
- Cable and Fuse Sizes, Mains Voltage 525–690 V, North America
- Cable Stripping Lengths
- Tightening Torques of the Terminals
- Power Ratings
- Power Ratings of VACON® 100 INDUSTRIAL, 380–500 V
- Power Ratings of VACON® 100 INDUSTRIAL, 525–600 V
- Power Ratings of VACON® 100 INDUSTRIAL, 525–690 V
- Power Ratings of VACON® 100 FLOW, 208–240 V
- Power Ratings of VACON® 100 FLOW, 380–500 V
- Power Ratings of VACON® 100 FLOW, 525–600 V
- Power Ratings of VACON® 100 FLOW, 525–690 V
- Power Ratings of VACON® 100 HVAC, 208–240 V
- Power Ratings of VACON® 100 HVAC, 380–500 V
- Brake Resistor Ratings
- Brake Resistor Types, Mains Voltage 208–240 V and 380–500 V
- Brake Resistance and Brake Power, Mains Voltage 208–240 V
- Brake Resistance and Brake Power, Mains Voltage 380–500 V
- Control Connections
- Technical Data, VACON® 100 INDUSTRIAL
- Technical Data, VACON® 100 FLOW
- Technical Data, VACON® 100 HVAC
|
10.6.6 Power Ratings of VACON® 100 FLOW, 380–500 VTable 36: Power Ratings of VACON® 100 FLOW, Mains Voltage 380–500 V, 50–60 Hz, 3~Enclo-suresizeDrive type (1) Low loadability:Continuous cur-rent IL [A] (2)Low loada-bility: Inputcurrent Iin[A] (2)Low loadabili-ty: 10% over-load current[A] (2)Low loadabil-ity: Max cur-rent Is 2 s (2)Motor shaftpower (3) : 10%overload 40°C[kW]Motor shaftpower (4) :10% over-load 40°C[hp]MR4 0003 3.4 3.4 3.7 5.2 1.1 1.50004 4.8 4.6 5.3 6.8 1.5 2.00005 5.6 5.4 6.2 8.6 2.2 3.00008 8.0 8.1 8.8 11.2 3.0 4.00009 9.6 9.3 10.6 16.0 4.0 5.00012 12.0 11.3 13.2 19.2 5.5 7.5MR5 0016 16.0 15.4 17.6 24.0 7.5 10.00023 23.0 21.3 25.3 32.0 11.0 15.00031 31.0 28.4 34.1 46.0 15.0 20.0MR6 0038 38.0 36.7 41.8 62.0 18.5 25.00046 46.0 43.6 50.6 76.0 22.0 30.00061 61.0 58.2 67.1 92.0 30.0 40.0MR7 0072 72.0 67.5 79.2 122.0 37.0 50.00087 87.0 85.3 95.7 144.0 45.0 60.00105 105.0 100.6 115.5 174.0 55.0 75.0MR8 0140 140.0 139.4 154.0 210.0 75.0 100.00170 170.0 166.5 187.0 280.0 90.0 125.00205 205.0 199.6 225.5 340.0 110.0 150.0MR9A 0261 261.0 258.0 287.1 410.0 132.0 200.00310 310.0 303.0 341.0 502.0 160.0 250.0MR9B 0386 385.0 386.0 423.5 620.0 200.0 300.01 The currents in given ambient temperatures are achieved only when the switching frequency is the same or smaller than the factory default2 See 10.7 Overload Capability.3 400 V4 480 VIf the process includes a cyclical load, for example if there are lifts or winches, speak to the manufacturer to get the dimensioninginformation.SpecificationsOperating Guide | VACON® 100 Wall-mounted DrivesAQ298036140958en-000101 / DPD01711120 | Danfoss A/S © 2019.05
PreviousNext |