Parameters130BB927.10FC+24 V+24 VD IND IND INCOMD IND IND IND IN+10 VA INA INCOMA OUTCOM12131819202729323337505354554239A53U - I4 - 20mA+-Function SettingParameter 6-12 Terminal 53 LowCurrent4 mA*Parameter 6-13 Terminal 53 HighCurrent20 mA*Parameter 6-14 Terminal 53 LowRef./Feedb. Value0 RPMParameter 6-15 Terminal 53 HighRef./Feedb. Value1500 RPM*=Default valueNotes/comments:Table 17.4 Analog Speed Reference (Current)17.3 Start/StopParametersFC+24 V+24 VD IND IND INCOMD IND IND IND IN+10A INA INCOMA OUTCOM12131819202729323337505354554239130BB802.10Function SettingParameter 5-10 Terminal 18Digital Input[8] Start*Parameter 5-12 Terminal 27Digital Input[0] NooperationParameter 5-19 Terminal 37 SafeStop[1] SafeTorque OffAlarm*=Default valueNotes/comments:If parameter 5-12 Terminal 27Digital Input is set to [0] Nooperation, a jumper wire toterminal 27 is not needed.Table 17.5 Start/Stop Command with Safe Torque Off130BB805.11SpeedStart (18)Illustration 17.1 Start/Stop with Safe Torque OffParametersFC+24 V+24 VD IND IND INCOMD IND IND IND IN+10 VA INA INCOMA OUTCOM12131819202729323337505354554239130BB803.10Function SettingParameter 5-10 Terminal 18Digital Input[9] LatchedStartParameter 5-12 Terminal 27Digital Input[6] StopInverse*=Default valueNotes/comments:If parameter 5-12 Terminal 27Digital Input is set to [0] Nooperation, a jumper wire toterminal 27 is not needed.Table 17.6 Pulse Start/StopSpeed130BB806.10Latched Start (18)Stop Inverse (27)Illustration 17.2 Latched Start/Stop InverseApplication Examples Design GuideMG37N102 Danfoss A/S © 6/2016 All rights reserved. 15317 17