VLT® FCD Series Operation & Display001001 Language(LANGUAGE)Value:✭English (ENGLISH) [0]German (DEUTSCH) [1]French (FRANCAIS) [2]Danish (DANSK) [3]Spanish (ESP ANOL) [4]Italian (ITALIANO) [5]Function:This parameter is used to choose the language tobe shown in the display whenever the LCP controlunit is connected.Description of choice:There is a choice of the languages shown. The fac-tory setting may vary.002002 Local/remote operation(OPERATION SITE)Value:✭Remote operation (REMOTE) [0]Local operation (LOCAL) [1]Function:There is a choice of two different modes of operationof the frequency converter; Remote operation [0] orLocal operation [1]. See also parameter 013 Localcontrol if Local operation [1] is selected.Description of choice:If Remote operation [0] is selected, the frequencyconverter is controlled via:1. the control terminals or via serial communication.2. The [START] key. This cannot, however, overridestop commands transmitted via the digital inputsor via serial communication.3. The [STOP/RESET] and [JOG] keys, on the con-dition that these are active.If Local operation [1], is selected, the frequency con-verter is controlled via:1. the [START] key. This cannot, however, overridestop commands via the digital inputs (see param-eter 013 Local control).2. The [STOP/RESET] and [JOG] keys, on the con-dition that these are active.3. The [FWD/REV] key, on the condition that is hasbeen selected as active in parameter 016 Localreversing, and that parameter 013 Local control isset at Local control and open loop [1] or Localcontrol as parameter 100 [3]. Parameter 200 Out-put frequency range is set at Both directions.4. parameter 003 Local reference where the refer-ence can be set using the [+] and [-] keys.5. an external control command that can be con-nected to the digital inputs (see parameter 013Local control).NB!:The [JOG] and [FWD/REV]keys are located on the LCP control unit.003003 Local reference(LOCAL REFERENCE)Value:Par.013 Local control must be set to [1] or [2]:0 - f MAX (par. 202) ✭ 000,000.000Par. 013 Local control must be set to [3] or [4] andparameter 203 Reference/feedback range to [0]:Ref MIN - Ref MAX (par. 204-205) ✭ 000,000.000Par. 013 Local control must be set to [3] or [4] andparameter 203 Reference/feedback range to [1]:- RefMAX - + Ref MAX (par. 204-205) ✭ 000,000.000Function:In this parameter, the local reference can be setmanually . The unit of the local reference depends onthe configuration selected in parameter 100 Configu-ration.Description of choice:In order to protect the local reference, parameter002 Local/remote operation must be set to Local op-eration [1]. Local reference cannot be set via serialcommunication. Setup configurationThere is a choice of four Setups (parameter Setups),which can be programmed independently of oneanother. The active Setup can be selected in param-eter 004 Active Setup. When an LCP control unit isconnected, the active Setup number will be appearin the display under “Setup”. It is also possible topreset the frequency converter to Multisetup, so thatit is possible to shift Setups using the digital inputsor serial communication. Setup shift can be used ina plant in which, for example, one Setup is used fordaytime operation and another one at night time.In parameter 006 Setup copying it is possible tocopy from one Setup to another. Using parameter007 LCP copy all Setups can be transferred from✭ = factory setting. () = display text [] = value for use in communication via serial communication portMG.04.A1.02 - VLT is a registered Danfoss trade mark48