The middle section on the display shows the parameternumber and name, as well as the selected parametervalue.130BP067.10740RPM0 -01 Language[0] English10.64A 1 [1]0-0*Basic SettingsIllustration 2.23 Parameter Selection2.1.8 Changing DataPress [OK] to change the selected parameter. Theprocedure for changing data depends on whether theselected parameter represents a numerical data value or atext value.2.1.9 Changing a Text ValueIf the selected parameter is a text value, change the textvalue with the [▲] [▼] keys.Place the cursor on the value that should be saved andpress [OK].130BP068.10740RPM0 -01 Language[0] English10.64 A 1 [1]0-0*Basic SettingsIllustration 2.24 Changing a Text Value2.1.10 Changing a Group of Numeric DataValuesIf the selected parameter represents a numeric data value,change the data value pressing the [◀] [▶] navigation keys,as well as the [▲] [▼] navigation keys. Press [◀] [▶] keys tomove the cursor horizontally.130BP069.101- 6*113 RPM 1.78 A 1(1)Load depen. setting1 - 60 Low speed loadcompensation100%Illustration 2.25 Changing a Group of Numeric Data ValuesPress the [▲] [▼] keys to change the data value. [▲]increases the data value, and [▼] decreases the data value.Place the cursor on the value to save and press [OK].130BP070.101 - 60 Low speed loadcompensation1 0%Load depen. setting 1- 6*729RPM 6.21A 1(1)6Illustration 2.26 Changing a Group of Numeric Data Values2.1.11 Value, Step-by-stepCertain parameters can be changed step by step. Thisapplies to:• Parameter 1-20 Motor Power [kW].• Parameter 1-22 Motor Voltage.• Parameter 1-23 Motor Frequency.The parameters are changed both as a group of numericdata values and as numeric data values that are infinitelyvarying.2.1.12 Read out and Programming ofIndexed ParametersParameters are indexed when placed in a rolling stack.Parameter 15-30 Alarm Log: Error Code toparameter 15-33 Alarm Log: Date and Time contain a faultlog which can be read out. Select a parameter, press [OK],and use the [▲]/[▼] navigation keys to scroll through thevalue log.Use parameter 3-10 Preset Reference as another example:Select the parameter, press [OK], and use the [▲]/[▼]navigation keys to scroll through the indexed values. Tochange the parameter value, select the indexed value andpress [OK]. To change the value, press the [▲]/[▼] keys.Press [OK] to accept the new setting. Press [Cancel] toabort. Press [Back] to leave the parameter.2.1.13 Initialization to Default SettingsInitialize the frequency converter to default settings in 2ways.Recommended initialization (viaparameter 14-22 Operation Mode)1. Select parameter 14-22 Operation Mode.2. Press [OK].3. Select [2] Initialization.How to Program VLT® Refrigeration Drive FC 10322 Danfoss A/S © 05/2016 All rights reserved. MG16H20222