12The Sharpening fixture is located on the rightside of the machine.Mounting the Sharpening fixture1. Rotate the locking lever so the flat edge is atthe top, horizontal and in a straight line withthe base casting.2. Position the sharpeningfixture so that the 2location holes on thebase of the alignment fixture are alignedwith the 3/8 dowel pins.3. After sharpeningfixture is in place,rotate the lockinglever clockwise untilsnug. This will securethe fixture to the base.Adjusting the Point AngleYou must loosen thesharpening fixture andslide the point angleindicator to the desireddegree.1. To loosen, pullthe lockinglever towardsyou.2. Place fingers on eachside of the sharpeningpivot base casting.3. Gently slide basecasting in eitherdirection to alignthe angleindicator with thedesired point angledegree.4. Secure the selectedpoint angle position bypushing the lockinglever away from youuntil it stops.5. Before sharpening, make sure the sharpeningfixture is secure and no longer slides in eitherdirection.Drill Sharpening