INTRODUCTION 2Focus Lock/UnlockOnce entered, the scanner automatically performs the Focus Lock procedure to save themechanical focus position to memory. If the mechanical focus position is changed by morethan the allowed tolerance of the value in memory, a diagnostic alarm will be sent to thedisplay.The procedure is as follows:- enter the Focus Lock function- wait until the "Focus locked at..." message appears on the display (indicating the focusposition has been saved to memory). The following parameters are set:• Locked Position = your mechanical setting• Focus Displacement (Alarm) = set (default to display only)If the Focus lock has already been set, this procedure can be used to Unlock the focus value.In this case control of the focus position is disabled.The scanner will restart at the end of the process.Reset Scanner to Factory DefaultIf it ever becomes necessary to reset the scanner to the factory default values, you canperform this procedure by holding the X-PRESS™ push button pressed while powering upthe scanner. At the end of the procedure (about 5-6 seconds), the Configuration andEnvironmental parameters are reset, all LEDs blink simultaneously 3 times and the message"Default Set" is shown on the display.2.4 ACCESSORIESThe following accessories are available on request for the DS4800:Name Description Part NumberBK-4000 L-Shape Bracket 93ACC1837BK-4001 U-Shape Bracket 93ACC1838CBX100 Compact Connection Box 93A301067CBX100LT Compact Connection Box Low Temp 93A301069CBX500 Modular Connection Box 93A301068BM100 Backup Module 93ACC1808BM150 Display Module 93ACC1809BM300/310 Profibus Module STD/IP65 93ACC1810, 93ACC1811BM400 DeviceNet Module IP65 93ACC1814BM500/510/520 Ethernet Module STD/IP65/IP54 93ACC1812, 93ACC1813,93ACC1840BA100 DIN Rail Adapters 93ACC1821BA200 Bosch Adapters 93ACC1822PH-1 Photocell Kit PNP 93ACC1791MEP-543 Photocell Kit NPN 93ACC1728PG-6000/6001/6002 24 V Power Supply Unit EU/UK/US 93ACC1720, 93ACC1719,93ACC171825