Datalogic QL300 Manual
Also see for QL300: Quick start guide
QL300 / QL500Quick Link ID-NET™ ConnectorsDESCRIPTIONThe QL series ID-NET™ connectors provide a fast and efficientway to cable an ID-NET™ network using standard cables. TheQL300/500s are typically Master ID-NET™ connectors designedto be used with the QL100/150/200s ID-NET™ Slave connectors.The QL300 is a passive connection module which can be used inStandalone or ID-NET™ Master Multidata, Slave Multidata orMaster Synchronized layouts. It provides separate ports forPower Supply, External Trigger, Digital I/O and Communication.Host communication is provided through connectivity to thereader Main serial interface (RS232/485) or Aux RS232 serialinterface.ID-NET™ network and power supply signals are sent out to thenext connected device by means of a dedicated port, howeverinput power is not received from the network. Therefore eachQL300 must be powered separately.The QL500 is an active connection module which can be used inStandalone or ID-NET™ Master Multidata, or MasterSynchronized layouts. It provides separate ports for PowerSupply, External Trigger, Digital I/O and Communication. Hostcommunication is provided through the integrated Ethernetmodule which connects internally to the reader's Main serialinterface. Reader Aux RS232 serial interface is also provided.ID-NET™ network and power supply signals are sent out to thenext connected device by means of a dedicated port, howeverthere is no network input connector and therefore it cannot beused as an ID-NET™ Slave.The QL series are compatible with the following readers:DS2100N DS4800 Matrix 400™DS2400N Matrix 200™QL300QL500CONNECTIONSID-NET OutM12 5P Female (A-coded)Pin Function1 Shield2 Vdc3 GND4 ID+5 ID-QL300 only (ID-NET In)M12 5P Male (A-coded)Pin Function1 Shield2 nc3 GND4 ID+5 ID-QL500 only (Ethernet)RJ45 8P FemalePin Function1 TX+2 TX-3 RX+6 RX-4, 5, 7, 8 ncP8 P1OVERALL DIMENSIONS129[4.56]42[1.49]45[1.59]56[1.98]76[2.67]27[0.95]QL300129[4.56]56[1.98]42[1.49]45[1.59]27[0.95]76[2.67]QL500PowerM12 3P Male (B-coded)Pin Function1 Earth2 Vdc3 GNDTriggerM12 4P Female (A-coded)Pin Function1 +V2 nc3 -V4 I1+MOUNTINGThere are two self-threading screws provided for mounting theQLs to various wooden or plastic surfaces. Mounting to othersurfaces such as concrete walls or metallic panels requires user-supplied parts (screws, screw anchors, nuts, etc). Keep in mindthat the connected reader must have its Chassis grounded toEarth, see paragraph "Grounding".QLs can also be mounted to a Bosch Frame using the BA200mounting accessory.The distance between mounting bushings is given in the overalldimension diagram for each QL.NOTEIP65 protection is provided when the cables (orQLs) are properly mated.GROUNDINGThere are two general rules to follow regarding networkgrounding:1) The network Shield must only be connected to Earthground at one point (the Master).When using isolated power supplies, Earth grounding can beaccomplished through the CAB-PW-EXT accessory cable andthe BA400 or QL300/500 Power connector.Power SupplyEarth ground connectionQL300PowerCAB-PW-EXT2) All reader Chassis must be connected to Earth ground.All the readers in the network must have their Chassisconnected to Earth ground either by: mounting toconductive metal brackets or frames which are connected toEarth ground; or through the CBX or SC4000; or through theQL bushing.In the case of grounding through the CBX or SC4000, connectthe Earth signal to a good earth ground and set the internalChassis jumper to Earth.In the case of grounding through the QL bushing, connect aflying lead from the mounting bushing to an Earth ground. Themounting bushing is internally connected to the readerChassis.* pins 4 and 5 are nc for QL500.* pins 4, 5, 12 and 15 are nc for QL500.CAUTIONDo not connect GND and SGND to different (external)ground references. GND and SGND are internallyconnected through filtering circuitry which can bepermanently damaged if subjected to voltage drops over0.8 Vdc.ACCESSORIESDescription Part Number ConnectionCablesCAB-PW-EXT M12 POWEREXTENSION CABLE93A051381 PowerCBL-1480-01 THIN M12/5PMALE/FEMALE 1MCBL-1480-02 THIN M12/5PMALE/FEMALE 2M970101021970101022 ID-NET Out/InTerminatorsCBL-1490 TERM. RESIST.THIN M12/5P/MALE970101069 ID-NET OutCBL-1496 TERM. RESIST.THIN M12/5P/FEMALE970101082 ID-NET InField Mountable ConnectorsFMC400 M12 3P F. CONN.POWER93ACC1884 PowerMountingBA200 Bosch Adaptors 93ACC1822The FMC accessory connectors can be used to make customExternal Power and Service cables in case the standard cablesdon't satisfy the application requirements.Reader25P D-Sub Female1142513Pin Function Pin Function1,shell,both bushingsReader Chassis2 TXM 14 nc3 RXM 15 nc4 RTSM * 16 nc5 CTSM * 17 nc6 I2A 18 I1A7 GND 19 GND8 O1+ 20 RXA9 nc 21 TXA10 I2B 22 O1-11 O2+ 23 ID+12 O2- 24 ID-13 Vdc 25 GNDI/O Port15P HD D-Sub Female161551110Pin Function Pin Function1 O1+ 9 I2A2 TXA 10 O2-3 RXA 11 I2B4 RXM * 12 TXM *5 CTSM * 13 GND6 O1- 14 SGND7 Vdc 15 RTSM *8 O2+mminmmin |
Related manuals for Datalogic QL300
manualsdatabase
Your AI-powered manual search engine