Datalogic QL300 Quick Start Manual
Also see for QL300: Manual
QL300 / QL500Quick Link ID-NET™ ConnectorsDESCRIPTIONThe QL series ID-NET™ connectors provide a fast and efficient way tocable an ID-NET™ network using standard cables. The QL300/500s aretypically Master ID-NET™ connectors designed to be used with theQL100/150/200s ID-NET™ Slave connectors.The QL300 is a passive connection module which can be used inStandalone or ID-NET™ Master Multidata, Slave Multidata or MasterSynchronized layouts. It provides separate ports for Power Supply,External Trigger, Digital I/O and Communication. Host communication isprovided through connectivity to the reader Main serial interface(RS232/485) or Aux RS232 serial interface.ID-NET™ network and power supply signals are sent out to the nextconnected device by means of a dedicated port, however input power isnot received from the network. Therefore each QL300 must be poweredseparately.The QL500 is an active connection module which can be used inStandalone or ID-NET™ Master Multidata, or Master Synchronizedlayouts. It provides separate ports for Power Supply, External Trigger,Digital I/O and Communication. Host communication is provided throughthe integrated Ethernet module which connects internally to the reader'sMain serial interface. Reader Aux RS232 serial interface is also provided.ID-NET™ network and power supply signals are sent out to the nextconnected device by means of a dedicated port, however there is nonetwork input connector and therefore it cannot be used as an ID-NET™Slave.Starting from software release 2.02.01 the QL500 also supports completeBackup & Restore functionality (Configuration and Environmentalparameter storage) for network, Master and up to 9 Slave devices. Seethe QL500 software release verification note on the opposite page.The QL series are compatible with the following readers:DS2100N Matrix 210™ Matrix 450™DS2400N Matrix 300™DS4800 Matrix 410™QL300QL500821001645 (Rev. E)CONNECTIONSID-NET OutM12 5P Female (A-coded)Pin Function1 Shield2 Vdc3 GND4 ID+5 ID-QL300 only (ID-NET In)M12 5P Male (A-coded)Pin Function1 Shield2 nc3 GND4 ID+5 ID-QL500 only (Ethernet)RJ45 8P FemaleP8 P1Pin Function1 TX+2 TX-3 RX+6 RX-4, 5, 7, 8 ncOVERALL DIMENSIONS129[4.56]42[1.49]45[1.59]56[1.98]76[2.67]27[0.95]QL300129[4.56]56[1.98]42[1.49]45[1.59]27[0.95]76[2.67]QL500CAUTIONConnect Input Power only to the 3-pin Powerconnector. Attempts to power the device from any otherconnector can result in damage to the connecteddevices.PowerM12 3P Male (B-coded)Pin Function1 Earth2 Vdc3 GNDTriggerM12 4P Female (A-coded)Pin Function1 +V2 nc3 -V4 I1+* pins 4 and 5 are nc for QL500.* pins 4, 5, 12 and 15 are nc for QL500.CAUTIONDo not connect GND and SGND to different (external)ground references. GND and SGND are internallyconnected through filtering circuitry which can bepermanently damaged if subjected to voltage drops over0.8 Vdc.MOUNTINGThere are two self-threading screws provided for mounting the QLs tovarious wooden or plastic surfaces. Mounting to other surfaces such asconcrete walls or metallic panels requires user-supplied parts (screws,screw anchors, nuts, etc). Keep in mind that the connected reader musthave its Chassis grounded to Earth, see paragraph "Grounding".QLs can also be mounted to a Bosch Frame using the BA200 mountingaccessory.The distance between mounting bushings is given in the overalldimension diagram for each QL.NOTEIP65 protection is provided when the cables (or QLs)are properly mated.GROUNDINGAll the readers in the network must have their Chassis and ID-NET™shield connected to Earth ground.For readers in the network connected through a CBX or SC4000, connectthe Earth signal to a good earth ground and set the internal Chassis and ID-NET™ shield jumpers to Earth.When using isolated power supplies, Earth grounding can beaccomplished through the CAB-PW-EXT accessory cable and the BA400or QL200/300/500 Power connector.Power SupplyEarth ground connectionBA400 or QLPower connectorCAB-PW-EXTFor readers in the network connected through QLs, there are two generalcases regarding network grounding:1. Grounding through conductive metal brackets or frames.When the QL connectors are mounted to conductive metal bracketsand/or frames it is sufficient to provide a good Earth ground to themetal frame. In this case all readers have their Chassis as well astheir ID-NET™ shield connected to Earth ground through the QLmounting bushings.2. Grounding to isolated (non-metallic) brackets or surfaces (i.e.plastic, wood, concrete).Connect a flying lead from the QL mounting bushing to an Earthground. The mounting bushings are internally connected to the readerChassis and to the ID-NET™ shield.ACCESSORIESDescription Part Number ConnectionCablesCAB-PW-EXT M12 POWEREXTENSION CABLE93A051381 PowerCBL-1480-01 M12/5PMALE/FEMALE 1M IDNETCBL-1480-02 M12/5PMALE/FEMALE 2M IDNET93A05004993A050050 ID-NET Out/InCAB-AUX04 15P DSUB TO DB9SERIAL CABLE 3M93A051386 I/O PortTerminatorsCBL-1490 TERM. RESIST.M12/5P/MALE IDNET93A050046 ID-NET OutCBL-1496 TERM. RESIST.M12/5P/FEMALE IDNET93A050047 ID-NET InField Mountable ConnectorsFMC400 M12 3P F. CONN. POWER 93ACC1884 PowerMountingBA200 Bosch Adaptors 93ACC1822The FMC accessory connectors can be used to make custom ExternalPower and Service cables in case the standard cables don't satisfy theapplication requirements.Reader25P D-Sub Female1142513Pin Function Pin Function1,shell,both bushingsID-NET™ shieldReader Chassis2 TXM 14 nc3 RXM 15 nc4 RTSM * 16 nc5 CTSM * 17 nc6 I2A 18 I1A7 GND 19 GND8 O1+ 20 RXA9 nc 21 TXA10 I2B 22 O1-11 O2+ 23 ID+12 O2- 24 ID-13 Vdc 25 GNDI/O Port15P HD D-Sub Female161551110Pin Function Pin Function1 O1+ 9 I2A2 TXA 10 O2-3 RXA 11 I2B4 RXM * 12 TXM *5 CTSM * 13 GND6 O1- 14 SGND7 Vdc 15 RTSM *8 O2+mminmmin |
Related manuals for Datalogic QL300
manualsdatabase
Your AI-powered manual search engine