Datalogic S5N-PA W Series Instruction Manual
This product is covered by one or more of the following patents.European Patent 851,211 B1; 1,111,690 B1; 1,148,346 B1; 1,209,487 B1.Italian Patent IT 1,321,772.S5N-PA/MA…WContrast sensorINSTRUCTION MANUALCONTROLSOUTPUT LEDThe yellow LED on indicates that the N.O. (normally open) output statusis closed.READY LEDThe green LED indicates a normal operating function.If the green LED flashes, the acquisition has failed.Please refer to the “SETTING” paragraph for setup procedureindications.SET PUSHBUTTONA long pressure on the pushbutton activates the self-setting procedure.INSTALLATIONS5N-PA…W : The sensor can be fixed by means of the M18x1 threadedbody through a 18 mm hole, using the specific washer and theenclosed 24 mm nuts (maximum torque of tightening 1.5 Nm).Alternatively, the sensor can be mounted through the two housing’s holesusing two screws (M3x22 or longer) and nuts.Amongst the various possible solutions, we suggest to choose thecombination that offers the best visibility of the signalling Leeds and theeasiest access to the SET pushbutton.22 mm nuts, h=8 mm, (2 Nm maximum tightening torque) are available toguarantee an improved torque.S5N-MA…W : The sensor can be fixed by means of the M18x1 threadedbody through a 18 mm hole, using the two CH.24 nuts enclosed (22Nm maximum tightening torque).For both plastic version and metallic version are available variousorientable fixing brackets to ease the sensor positioning (please refer tothe accessories listed in the general catalogue).The operating distance is measured from the front surface of the sensorlens.CONNECTIONSThe connections are compliant to the EN 60947-5-2 standard.+ 10 … 30 VdcN.C. OUTPUTBROWN 1WHITE 2BLACK 4BLUE 3N.O. OUTPUT0 VM12 CONNECTOR10 … 30 Vdc-+N.O. OUTPUT0 VN.C. OUTPUT(WHITE) (BROWN)(BLUE) (BLACK)2314DIMENSIONS24=N°.2 Ø3.84=2.5=4=3.82STABILITY LEDmm10Ø4OUTPUT LED OUTPUT LEDSTABILITY LED81.543CABLE VERSION=2.544SET PUSHBUTTON=2414.525M18x1143.5M12101.549M18x110M12S50-PA VERSIONS S50-MA VERSIONS14.5STABILITY LEDOUTPUT LEDSTABILITY LEDOUTPUT LED10Ø4CABLE VERSION6743SET PUSHBUTTON1534TECHNICAL DATAS5N-PA PLASTIC VERSIONS S5N-MA METALLIC VERSIONSPower supply: 10 … 30 Vdc (limit values)Ripple: 2 Vpp max.Current consumption(output current excluded): 25 mA max.Outputs: N.O. and N.C.; PNP or NPN; 30 Vcc max. (short-circuit protection)Output current: 100 mA max.Output saturation voltage: 2 V max.Response time: 100 sSwitching frequency: 5 kHzJitter 50 sIndicators: OUTPUT LED (YELLOW) / LED READY (GREEN)Setting: SET pushbuttonOperating mode: LIGHT mode on N.O. output / DARK mode on N.C. outputData retention: non volatile EEPROM memoryOperating temperature: -10 … 55 °CStorage temperature: -20 … 70 °CInsulating strength: 500 Vac 1 min., between electronics and housingInsulating resistance: >20 M 500 Vdc, between electronics and housingOperating distance (typical values): 10 mm 2 mmMinimum spot dimension: 4.5mmEmission type: white light LED (400-700 nm)Ambient light rejection: according to EN 60947-5-2Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27)Housing: PBT Nickel plated brassLenses: PMMAMechanical protection: IP67 Metal versions type 1 enclosureConnections: 2 m cable 4 mm / M12 - 4 pole connectorWeight: 75 g. max. cable vers.25 g. max. connector vers.110 g. max. cable vers.60 g. max. connector vers.AtEx 2014/34/EU II 3D EX tc IIIC IP67 T85°CEmission: Exempt Risk Group (RG0) according to IEC 62471SETTINGEASY TOUCHThe sensor uses the patent-covered EASY TOUCH technology thatallows a rapid and safe self-setting of the product.Two different setting possibilities are available:- EASY TOUCH ; a long pressure of the SET pushbutton allows self-setting.- FINE DETECTION; to be used only in particularly critical conditions,this setting procedure is used only when the EASY TOUCH is notsufficient.Setting of S5N-PA/MA…WTo achieve a correct sensor functioning, the coloured mark or object tobe detected has to be placed at the right reading distance.- EASY TOUCH (standard detection in the DARK mode)The EASY TOUCH technology allows the functioning in the DARKmode (mark presents a lower light intensity respect to thebackground).The mark to detect has to be placed correctly at the right readingdistance within the sensor spot.Press the SET pushbutton until the READY LED turns OFF.Release the SET pushbutton and wait for the READY LED to turn ON.The sensor is now ready to detect the pre-set coloured mark or object(output LED turns ON when the N.O. output is closed).- Fine detection (DARK or LIGHT mode)This mode offers an improved detection precision.The sensor can function either in the DARK operating or in the LIGHToperating mode (light-coloured mark on dark background).The operating mode is selected automatically by the sensor.The mark to detect has to be placed correctly at the right readingdistance within the sensor spot.Press the SET button until the READY LED turns OFF.Hold the SET button until the READY LED turns ON (3s).The sensor is acquiring the mark.When the READY LED flashes slowly, position the background tocoincide with the sensor spot and press the SET button again.If the READY LED lights up permanently, the acquisition has beensuccessful; if the LED flashes quickly, the acquisition has failed due toinsufficient contrast. Pressing the SET button returns the sensor tothe previous setting. Repeat the procedure from the beginning.The output LED is ON and the N.O. output is closed, when the sensoris positioned on the pre-set coloured mark.Datalogic S.r.l.Via S. Vitalino 13 - 40012 Calderara di Reno - ItalyTel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.comHelpful links at www.datalogic.com: Contact Us, Terms and Conditions,Support.For information about the disposal of Waste Electricaland Electronic Equipment (WEEE), please refer to thewebsite at www.datalogic.com.© 2007 - 2020 Datalogic S.p.A. and/or its affiliates ALL RIGHTSRESERVED. Without limiting the rights under copyright, no part of thisdocumentation may be reproduced, stored in or introduced into a retrievalsystem, or transmitted in any form or by any means, or for any purpose,without the express written permission of Datalogic S.p.A. and/or itsaffiliates. Datalogic and the Datalogic logo are registered trademarks ofDatalogic S.p.A. in many countries, including the U.S.A. and the E.U. Allother trademarks and brands are property of their respective o wners.Datalogic reserves the right to make modifications and improvementswithout prior notification.826000442 Rev.CS5N-PA VERSION S5N-MA VERSIONREADY L ED READY L ED READY L ED READY L ED |
Related manuals for Datalogic 952001321
Datalogic S5N-PA U Series Instruction Manual
Datalogic S5N-PL Series Instruction Manual
Datalogic S51-PA Series Instruction Manual
Datalogic S5N-M Series Instruction Manual
Datalogic S5N-M Series Instruction Manual
Datalogic S5N-M PP Series Instruction Manual
Datalogic S51-MA Series Instruction Manual
Datalogic S5N-Px-PP/NN Series Instruction Manual
Datalogic IO-Link S5N-P Series Instruction Manual
Datalogic S62 Series Instruction Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine