Datalogic SG-M Instruction Manual
SG-MINSTRUCTION MANUALSystem is compatible with all Datalogic SG safety light curtains with muting function feature.For correct use and safety prescriptions refer to the user manual of Datalogic safety light curtains wheremuting kit is installed.With modular muting systems it is possible to arrange multiple configurations.MODEL DESCRIPTION ORDER NUMBERSG-ML-S8-LKit for L Muting, left side: 2 sensors S8-PR-3-B01-PP with a 0.7mcable with M12 connector; 2 reflectors; 1 active arm; 1 passivearm; 2 cable-lockers95ASE2600SG-ML-S8-RKit for L Muting, right side: 2 sensors S8-PR-3-B01-PP with a0.7m cable with M12 connector; 2 reflectors; 1 active arm; 1passive arm; 2 cable-lockers95ASE2370SG-ML-S8-200-LKit for L Muting, left side: 2 sensors S8-PR-3-B01-PP with a 2mcable with M12 connector; 2 reflectors; 1 active arm; 1 passivearm; 2 cable-lockers95ASE2590SG-ML-S8-200-RKit for L Muting, right side: 2 sensors S8-PR-3-B01-PP with a 2mcable with M12 connector; 2 reflectors; 1 active arm; 1 passivearm; 2 cable-lockers95ASE2340SG-ML-S100-LKit for L Muting, left side: 2 sensors S100-PR-5-B10-PK;2 reflectors; 1 active arm; 1 passive arm; 2 cable-lockers;2x 700mm cables with M12 connectors95ASE2620SG-ML-S100-RKit for L Muting, right side: 2 sensors S100-PR-5-B10-PK;2 reflectors; 1 active arm; 1 passive arm; 2 cable-lockers;2x 700mm cables with M12 connectors95ASE2430SG-ML-S100-200-LKit for L Muting, left side: 2 sensors S100-PR-5-B10-PK;2 reflectors; 1 active arm; 1 passive arm; 2 cable-lockers;2 x 2000mm cables with M12 connectors95ASE2610SG-ML-S100-200-RKit for L Muting, right side: 2 sensors S100-PR-5-B10-PK;2 reflectors; 1 active arm; 1 passive arm; 2 cable-lockers;2 x 2000mm cables with M12 connectors95ASE2400MODEL DESCRIPTION ORDER NUMBERSG-MT-S8Kit for T Muting: 4 sensors S8-PR-3-B01-PP with a 0.7m cablewith M12 connector; 4 reflectors; 2 active arms; 2 passive arms; 4cable-lockers95ASE2380SG-MT-S8-200Kit for T Muting: 4 sensors S8-PR-3-B01-PP with a 2m cable withM12 connector; 4 reflectors; 2 active arms; 2 passive arms; 4cable-lockers95ASE2350SG-MT-S100Kit for T Muting: 4 sensors S100-PR-5-B10-PK;4 reflectors; 2 active arms; 2 passive arms; 4 cable-lockers;4 x 700mm cables with M12 connectors95ASE2440SG-MT-S100-200Kit for T Muting: 4 sensors S100-PR-5-B10-PK;4 reflectors; 2 active arms; 2 passive arms; 4 cable-lockers;4 x 2000mm cables with M12 connectors95ASE2410MODEL DESCRIPTION ORDER NUMBERSG-MX-S8Kit for X Muting; 2 sensors S8-PR-3-B01-PP with a 0.7m cablewith M12 connector; 2 reflectors; 2 active arms; 2 passive arms; 4cable-lockers95ASE2390SG-MX-S8-200Kit for X Muting; 2 sensors S8-PR-3-B01-PP with 2m cable withM12 connector; 2 reflectors; 2 active arms; 2 passive arms; 4cable-lockers95ASE2360SG-MX-S100Kit for X Muting; 2 sensors S100-PR-5-B10-PK;2 reflectors; 2 active arms; 2 passive arms; 4 cable-lockers;700mm pigtail cables with M12 connectors95ASE2450SG-MX-S100-200Kit for X Muting; 2 sensors S100-PR-5-B10-PK;2 reflectors; 2 active arms; 2 passive arms; 4 cable-lockers;2000mm pigtail cables with M12 connectors95ASE2420MOUNTING Put the arm slider (1) into the column slot (2).Fix the arm (3) in the desired position by screws (4), 1 Nm recommended tightening torque. Rotate sensors/reflectors support (5) in the desired position ; if necessary, translate support removingand spacing cable-locker (6) and fix by screws (7), 2 - 3 Nm recommended tightening torque. Loosen the two screws (8) and rotate/set the sensor/reflector as desired, then fix by screws (8),1 Nm recommended tightening torque.NOTE: For It is recommended to use the Datalogic SG-M-CB connection box for electrical connections of theSG-M kit to the Datalogic safety curtains. For each muting system kit it is recommended to use the same sensors type kit. Sensors must be set on Dark Mode.Datalogic S.r.l.Via S. Vitalino 13 - 40012 Calderara di Reno - ItalyTel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.comHelpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.The warranty period for this product is 36 months. See General Terms and Conditions of Sales for further details.Under current Italian and European laws, Datalogic is not obliged to take care of product disposal at the end of its life. Datalogicrecommends disposing of the product in compliance with local laws or contacting authorised waste collection centres.© 2015 - 2017 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED. Without limiting the rights under copyright, no part of thisdocumentation may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means, or for anypurpose, without the express written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registeredtrademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks and brands are property of theirrespective owners. Datalogic reserves the right to make modifications and improvements without prior notification.821003472 Rev.B“R”“L”L-MUTINGT-MUTINGX-MUTING |
Related manuals for Datalogic SG-M
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine