32oscillator frequency to glide from the step three value when step four is gatedon. The higher the Slew value, the slower the slew rate. And the slew rate can bedifferent for each step. But its not just for oscillator glide. Slew can be applied toany of the destinations. For example, sequence three could be routed to filtercutoff with Slew in sequence four used to create a less abrupt transition fromone step to the next.Note: Depending upon the BPM and Clock Divide settings, the slew ratecan actually exceed the time the envelopes are gated on, causing a step inthe affected sequence to not reach its set value. For example, if Slew isapplied to oscillator frequency, high Slew values may cause a step tosound flat or sharp. If that’s not what you want, simply reduce the Slewvalue.Syncing an LFO to the SequencerOne very useful way to modulate a parameter in sync with a sequence is usingan LFO with Clock Sync. A setting of 16 Steps for LFO Frequency with atriangle wave selected and routed to the filter will provide a clean filter sweepover a 16-step sequence, perfectly in sync! This is much easier (and smoother)than manually programming a sequence to sweep the filter.Name ParameterEdit Name — The lower LCD line displays the name of the Program with theactive character blinking. When A SSIGN P ARAMETERS is lit, the parametercontrol changes the position of the active character and S ELECT and theincrement (+) and decrement (-) buttons change the character.