7ENGLISHI n s t a l l a t i o n I n s t r u c t i o n s1. Allow at least 12 inches (30cm) of space on all sides of the unit for good air circulation.2. Install your dehumidifier on a floor, table, or shelf. When installing the unit on a table or shelf,make sure the table or shelf is strong enough to support the weight of the unit with a fullbucket.Note: The dehumidifier needs to be secured when installed on a table or a shelf.Do not sit or stand on the dehumidifier.3. The tank must be properly positioned.4. Castor wheels let you move the dehumidifier easily.Choosing the proper location for the unit1. Use the unit in a basement to help prevent moisture damage.2. Use the unit in cooking, laundry, bathing, and dishwashing areas that have excessive moi-sture.3. Use the unit to prevent moisture damage anywhere books or valuables are stored.4. Place the unit where you want to have comfortable conditions.List of componentsFor models equipped with pump system:• 16 ft. (5 m) clear hose with Quick-Connect connection• 3 ft. (1 m) clear hoseFor all other models:• 3 ft. (1 m) clear hoseRequired tools and assembly timeCollection tank:No assembly or plumbing necessary.Continuous draining outlet:To use the Continuous Draining feature the following tools will be necessary:• 5 mm (0.2 in.) drill bit (to drill open the draining outlet)• Drill toolThe estimated assembly time is 1-2 minutes.Pump system and Quick-Connect 16ft. hose (only on models equipped with pump system):No tools necessary. The estimated assembly time is 1-2 minutes.1 2 i n .( 3 0 c m )1 2 i n .( 3 0 c m )