18TECHNICAL DATAMains voltage: ..........................................220-240V~50/60HzAbsorbed power: ............................................................1100WPressure: .........................................................................15 barWater tank capacity: ................................................... 1,4 litresDimensions .............................. LxHxP255x315x280 (395) mmPeso ...............................................................................Weight3,9 kg mmTROUBLESHOOTING...Problem Possible causes SolutionNo espresso coffee is delivered No water in the tank Fill the tank with waterThe holes in the filter holder are blocked Clean the filter holder spout holesThe espresso boiler outlet is blocked Clean as described in the chapter “Cleaning”Limescale in the water circuit Descale as described in the section “Descaling”The espresso coffee drips fromthe edges of the filter holderrather than the holesThe filter holder has been inserted incor-rectly or is dirtyAttach the filter holder correctly and rotate firmlyas far as it will goThe espresso boiler gasket has lost elasti-city or is dirtyHave the espresso boiler gasket replaced by Custo-mer ServicesThe holes in the filter holder spouts areblockedClean the filter holder spout holesThe espresso coffee is cold The coffee OK light was not on when thecoffee button was pressed.Wait until the OK light comes onNo preheating was done Preheat as described in the paragraph “Tips for ahotter coffee”.The cups were not preheated Heat the cups by rinsing them in hot water or le-aving them to rest for at least 20 minutes on thecup warmer tray.Limescale in the water circuit Descale as described in the section “Descaling”The pump is excessively noisy The water tank is empty Fill the tankThe tank is incorrectly inserted and thevalve on the bottom is not openPress the tank down lightly to open the valve onthe bottomThere are air bubbles in the tankconnectorFollow the instructions given in the “Hot water”section until water is deliveredThe appliance complies with the following ECdirectives:• Low Voltage Directive 2006/95/EC and subsequentamendments;• EMC Directive 2004/108/EC and subsequent amendments;• European Standby Regulation 1275/2008 and subsequentamendments;• Materials and accessories coming into contact with foodconform to EEC regulation 1935/2004.