355 ELECTRICAL CONNECTIONSExecute the wiring following the directions of table 1 and diagrams.WARNING For adequate electrical safety, keep low safety voltage wires (controls, electro-locks, antenna, auxiliary power) clearly separatefrom 230V ~ power wires (minimum 4 mm in air or 1 mm via supplementary insulation) placing them in plastic raceways and securingthem with adequate clamps near terminal boards.WARNING For connection to the mains, use a multipolar cable having a minimum section 3x1,5 mm² and complying with the currentregulations. For connecting the motors, use a minimum cross section 1,5 mm² cable and complying with the current regulations. Asan example, if the cable is out side (outdoor), must be at least equal to H07RN-F, whereas if it (in a raceway), must be at least equal toH05VV-F.WARNING All wires must be striped and unsheathed in the immediate vicinity of terminals. Keep wires slightly longer to subsequentlyeliminate any excess.WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm2 .Table 1 “terminal board connections”3-4 22 V ~ transformer power supply input5-6 24 V battery power supply or photovoltaic accumulator Green Energy input (follow carefully polarity indications).7-8 Operator 1 output9 Connection of motors metallic parts10-11 Operator 2 output (if present)12-13 24 V max 15 W output for open gate fix warning light (if P052=0), flashing (if P052=1) or courtesy light (ifP052>1)14-1514 (-) “Boost” output for electric-lock, max 1 x art. 110 (if P062=0), 24V pulse output, max 5W (if P062=1), stepby step (if P062=2), electro-brake output for not self-locking operators (if P062=3), output for electric-lockpower supply via external relay (if P062=4), output for electro-magnets power supply for barriers (ifP062=5)or temporized output (if P062>5).15 (+)16-17 24 V Flashing light output max 15W art. LED24AITYPE 00 TYPE 01 TYPE 02 TYPE 03If the installation requires different commands and / or ad-ditional to the standard, you can configure each input to therequired rate.Refer to Chapter“Advanced Programming”.If unused, short circuit18 - IN_6 Input 6 (FCC 1) (STOP) (NONE) (NONE)19 - Com N.C. N.C. N.O. N.O.20 - IN_5 Input 5 (FCA 1) (PHOTO 2) (NONE) (NONE)21 - Com N.C. N.C. N.O. N.O.22 - IN_4 Input 4 ( PHOTO 1) (PHOTO 1) (STOP) (NONE)23 - Com N.C. N.C. N.C. N.O.24 - IN_3 Input 3 (SAFETY) (SAFETY) (SAFETY) (NONE)25 - Com N.C. N.C. N.C. N.O.26 - IN_2 Input 2 (PEDESTRIAN) (PEDESTRIAN) (PHOTO 1) (PHOTO 1)27 - Com N.O. N.O. N.C. N.C.28 - IN_1 Input 1 (START) (START) (START) (START)29 - Com N.O. N.O. N.O. N.O.30 Aerial signal input31 Ground aerial input32-33 32 (+)24 V power supply output for auxiliary devices (AUX + ST)=max 200mA33 (-)1-2 1 (-)Stabilized 24 V power supply output for tested safety devices2 (+)J5 J9 Encoder selection Jumper:•A position = operators with encoder (remind to set P029=0)•B position = operators without encoder (remind to set P029=1)AB AB