1-101.16 Element Wattage/Amperage Calculation ChartsUse the charts below when changing voltages or determining amperage for a given elementconfiguration.L1L2L3Three PhaseAmperageTo determine Three Phase Amperage, solve forSingle Phase first:= Single Phase AmpsVoltageWattage240V17,000W= 40.944 Amps per PhaseThen divide the Single Phase Amperage by 1.73 todetermine Three Phase Amperage.1.7370.833 Amps=Example:L1L2L3Three PhaseWattage= New Wattage Rating[ ]Old VoltageNew Voltage 2kW ListedXIf 208V supply is applied to a 17 kW elementrated for 240V, the calculation is as follows:[ ]240V208V 217,000 WattsX= 12.77 kWExample:To compute the New Wattage Rating of an element if adifferent voltage is applied, use the following formula:1.17 Troubleshooting1.17.1 Control and Heating ProblemsProblem Probable Causes Corrective ActionA. Power cord is not plugged in or circuitbreaker is tripped.A. Plug power cord in and verify thatcircuit breaker is not tripped.B. Controller has failed.B. If available, substitute a controllerknown to be working for thesuspect controller. If the substitutecontroller functions correctly, ordera new controller.Controller won'tactivate.C. Power supply component ortemperature control board has failed.C. If any of the components in thepower supply system (including thetransformer and temperature controlboard) fail, power will not besupplied to the controller and it willnot function.