DEAN MILLIVOLT GAS FRYERS (NON-CE)CHAPTER 2: IMPORTANT INFORMATION2-42.5 Pre-Installation (cont.)C. Installation Standards1. INSTALLATION STANDARDS: Fryer installation must conform with local codes, or inthe absence of local codes, to the appropriate national standards as listed below:a. U.S. installations must meet: b. Canadian installations must meet:American National Standard Institute CAN 1-B149 Installation CodesANSI Z83.11 Canadian Gas AssociationAmerican Gas Association 55 Scarsdale Road8501 E. Pleasant Valley Road Don Mills, ONT, M3B 2R3Cleveland, OH 44131National Electrical Code Canadian Electric Code c22.1, part 1ANSI/NFPA #70 Canadian Standards AssociationAmerican National Standard Institute 178 Rexdale Blvd.1430 Broadway Rexdale, ONT, M9W 1R3New York, NY 10018NFPA Standards #96 and #211National Fire Protection Association470 Atlantic AvenueBoston, MA 02110D. Australian RequirementsTo be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any otherrelevant statutory regulations.2.6 Equipment Installed at High Altitudes1. The fryer input rating [BTU/hr (kW/hr)] is for elevations up to 2,000 feet (610-m). Forelevations above 2,000 feet (610-m), the rating should be reduced 4-percent for each additional1,000 feet (305-m) above sea level.2. The correct orifices are installed at the factory if the operating altitude is known at the time of thecustomer’s order.