SUPER RUNNER SERIES GAS FRYERSCHAPTER 2: OPERATION2-3DANGER"Dry-firing" the fryer will cause damage to the frypot and can cause a fire. Always ensure that shortening,cooking oil or water covers the burner tubes before lighting the burners.2. With the pilot lit, push down and slowly turn the gas valve knob to the ON position.3. Rotate the operating thermostat knob to the desired frying temperature. The burner should light and burn with astrong blue flame.DANGERIf the pilot and burners go out, the fryer must be completely shut down at least five minutes before re-lighting.2.2 Shutting the Fryer DownFor temporary shutdown, turn the operating thermostat to the OFF position and cover the frypot.For complete shutdown, turn the operating thermostat to the OFF position, turn the gas valve knob to the OFF position(Non-CE) or press the red button (CE) and cover the frypot.2.3 Daily Operation1. Do not allow grease to accumulate or harden on the frame, body, or flue of the fryer. Clean the fryer inside and outwith a solution of detergent and hot water daily.2. Filter the cooking oil by draining the frypot through a filter cone at least daily. After the oil has been drained fromthe frypot, remove any residue from the pot, using a scraper if necessary.3. Clean the frypot at least once each week by filling it to just below the upper oil level mark with water. Add one cupof detergent and bring the solution to a boil. Allow the solution to simmer for 10-15 minutes, then drain and rinsethe frypot with clean water twice. Add ¼ cup of white vinegar to the last rinse to neutralize any alkalinity remainingfrom the detergent. Wipe the frypot surfaces with a dry towel before refilling with cooking oil. If the fryer is not tobe used immediately after cleaning, it is suggested that the inside of the frypot be wiped down with a light coat ofcooking oil to prevent rust.2.4 Recommended Spare PartsDESCRIPTIONPART #SR42- NON-CEPART #SR42- CEPART #SR52/SR62- NON-CEPART #SR52/SR62- CEOperating Thermostat 807-3515 807-1692 807-3515 807-1692High-Limit Thermostat 807-3516 807-3560 807-3680 807-3560Thermopile 810-2033 807-3565 810-2033 807-3565Thermocouple N/A 812-1284 N/A 812-1284Pilot Burner, Natural Gas 810-2032 810-2032 810-2032 810-2032Pilot Burner, Propane Gas 810-2155 810-2155 810-2155 810-2155Pilot Bracket, AGA N/A 200-6564 N/A 200-6564Pilot Thermopile Bracket N/A 810-2401 N/A 810-2401Piezo Ignitor Trigger N/A 810-1001 N/A 810-1001Piezo Ignitor Bracket N/A 200-1868 N/A 200-1868Piezo Ignitor Electrode N/A 807-3540 N/A 807-3540Orifice, Natural 810-2040 810-2060 810-2048 810-2060Orifice, Natural, units built after 4/07 810-3097 810-3101 N/A N/AOrifice, Propane 810-2064 810-2059 810-2059 810-2059Orifice, Propane, units built after 4/07 810-3099 810-3102 N/A N/AGas Valve, Natural 807-1603 807-2122 807-1603 807-2122Gas Valve, Propane 807-1604 807-2121 807-1604 807-2121Leg 810-2053 810-2053 810-2053 810-2053Caster, 5-inch w/o Brake 810-0356 810-0356 810-0356 810-0356Caster, 5-inch w/Brake 810-0357 810-0357 810-0357 810-0357