3 INSTALLING THE SENSORS EC-5ing soil. Be careful not to bend the black overmolding connecting thesensor to the cable.To watch a video on proper installation of the sensor go towww.decagon.com/install.OrientationThe sensor can be oriented in any direction. However, orientingthe flat side perpendicular to the surface of the soil will minimizeeffects on downward water movement.Removing the SensorWhen removing the sensor from the soil, do not pull it out of the soilby the cable! Doing so may break internal connections and make thesensor unusable.3.1 WiringFigure 1: 3.5 mm Stereo PlugThe following software support the EC-5 sensor:• ECH2O Utility 1.12 or greater• ECH2O DataTrac 2.77 or greaterConnecting to a non-Decagon LoggerCustomers may purchase EC-5 sensors for use with non-Decagon6