Dedicated Micros TransVu Express Quick Start Manual
Quick Start GuideMI-Q-TVE/E2-0Installing the Hard DriveThe hard drive for the unit is provided un-installed.1) Unlock the keylock on the front of the TransVu Express and withdrawthe caddy.2) Remove from the protective packaging from the Hard drive and insertinto the caddy. Ensure the pins on the hard drive are pointing awayfrom the front of the caddy drawer and the label on the hard driveis facing upwards and visible when the hard drive is placed in thecaddy.3) Carefully slide the caddy back into the TransVu Express. Rememberto lock the caddy into the TransVu Express using the keylock. Failureto do so will prevent the unit starting up.ConnectionsPlease ensure the following are available and have been tested prior to theinstallation:• 10 ~ 30VDC Vehicle Power Source• Crossed network cable required for web page setup• Active video signals.• Correctly terminated cable loom, please see TransVu Expressinstallation manual for further information.• Desk or Laptop PC with CD ROM drive with Internet Explorer 5.5upwards for unit configuration• Note that pin 35 of the connector provides a switched output of theinput voltage NOT a 12V regulated supplyWARNING: Operate the TransVu Express from the power sourceindicated on the label. Failure to do so may cause injury, andwill invalidate the warranty. Under no circumstances makeconnections to this unit whilst power is applied.37 way Connector LayoutNumbers looking at the front of the male connector.1 193720Read the Instructions FirstRead all safety and operating instructions and labels before working with theTransVu Express. This Quick Start Guide is not for use in isolation and shouldalways be used in conjunction with the main user manuals.Please contact the supplier with any problems. Report any difficulties with thisguide to Dedicated Micros at the UK office. Addresses and phone numbersare given in the user guides and also in the Contacts area of the website at:http://www.dedicatedmicros.comServicingDo not attempt to service this unit. Opening or removing covers may exposedangerous voltages or other hazards. Refer all servicing to qualified servicepersonnel.Lifting and HandlingAlways follow health and safety guidelines when lifting the unit from the boxor installing the TransVu Express unit.UnpackingRemove all the items from the box and check components listed below areincluded.The TransVu Express package contains the following items:• TransVu Express unit• Mounting Plate• Rubber Shock Mounts• Installation CD ROM• Installation Guide• Configuration & Operation Guide• Setup Guide• Quick Start Guide (this document)If any of these items are missing, please contact the distributer CustomerServices department.Location• Drilling extra holes in the casing of the unit will immediately invalidatethe warranty.• The unit should be mounted away from any possible places wherewater may puddle during vehicle operation as the TransVu Expresscasing is not rated for submersion.The unit should be mounted on a secure base free from resonance andsecondary vibrations using the mounting plate provided.• A fitment area of 290mm x 190mm x 90mm (11½” x 7½” x 3½” ) isrequired.• Extra space is required around to the plug area to ensure easyremoval.• Refer to TransVu Express Installation and Configuration & OperationGuides for more information.Pin Description1 Monitor Output (1V p-p CVBS video)2 Video ground3 Camera 8 (1V p-p CVBS video)4 Camera 5 (1V p-p CVBS video)5 Video ground6 Camera 4 (1V p-p CVBS video)7 Camera 1 (1V p-p CVBS video)8 Audio ground9 Audio Input 2 (mic-level)10 Relay output (negative side)11 COM3 port: RS-232 TXD12 10/100 Ethernet port: TX+13 10/100 Ethernet port: TX-14 Alarm Input 115 Alarm Input 316 Switched power output – negative17 Power input - negative: ground18 Power input - negative: ground19 Video groundPin Description20 Camera 7 (1V p-p CVBS video)21 Camera 6 (1V p-p CVBS video)22 Video ground23 Camera 3 (1V p-p CVBS video)24 Camera 2 (1V p-p CVBS video)25 Video ground26 Audio Input 1 (line-level)27 Relay output (positive side)28 Alarm ground29 Alarm Input 230 Ignition sense input31 COM3 port: RS-232 RXD32 COM3 ground33 10/100 Ethernet port: RX+34 10/100 Ethernet port: RX-35 Switched power output – positive (1A)36 Power input - positive: 10V – 30V DC37 Power input - positive: 10V – 30V DC15 way Expansion Port LayoutNumbers looking at the front of the male connector.165101511PIN NO. FUNCTION1 POWER MANGER RS232-RXD2 POWER MANGER RS232-TXD3 GND4 COM1 RS232-RXD5 COM1 RS232-TXD6 COM2 - RS485+/RS422_TX+7 COM2 - RS485-/RS422_TX-8 GND9 COM1 CTS10 COM1 RTS11 COM2 - RS422_RX+12 COM2 - RS422_RX-13 GND14 AUDIO OUT 0 line level15 AUDIO OUT 1 line level |
Related manuals for Dedicated Micros TransVu Express
Dedicated Micros SD Unit Quick Start Manual
Dedicated Micros Eco4 Series Quick Start Manual
Dedicated Micros SDA-32-6T Quick Start Manual
Dedicated Micros DV-IP Series Quick Start Manual
Dedicated Micros Eco9 Setup Manual
Dedicated Micros D4 Setup Manual
Dedicated Micros D3 Setup Manual
Dedicated Micros SD Excel Installation Manual
Dedicated Micros Digital Sprite 2 Manual
Dedicated Micros D4 Setup Manual Addendum
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine