7.3 ParametersFor a detailed description of the configuration parameters please refer to the document“UDL/UDK deBus protocol”. Application notes regarding the configuration settings can befound at “deister RFID Portal“ (www.deister.com – deister RFID Portal). If transponder typeEPC class1 gen2 is used, the configuration parameters refer to the specification ofEPCglobal™ (EPCglobal™, Class 1 Generation 2 UHF Air Interface Protocol Standard).7.3.1 Basic SetupOperating ModeSingle reader for operating of a single reading-/writing devicePortal mode for operating several reading-/writing devices using a dataconcentration unit (DCU1)Trigger mode for operating of a reading-/writing device using the trigger modeAnticollisionsingle tag in field operation mode for reading transponder data, in case there isonly one tag in the field (anticollision deactivated)handle multiple tags operation mode for reading transponder data, in case there ismore than one tag in the field (anticollision activated)Regulatory SettingsSelection of the regulation used by reader ETSI 302 208 (EU)ETSI 300 220 (EU), optionalFCC Part 15 (US), optionalTransponder Typeselection of transponder type, which has to be read/writtenRead contentSerial number reading the EPCRead mode for reading transponder dataWrite mode for writing a transponder22 deister electronic GmbH 30890 Barsinghausen Germany V17/01/08Wiring & Installation Instructions UDL500