3000-4, 2000-5 NG/LP Page 1320. The ignition control and pilot burner must both be chassis grounded.21. Handle the pilot-electrode assembly carefully. If damaged, replace entire assembly. The correct sparkgap should be 7/64" to 1/8".22. The pilots must be securely mounted relative to the main burner in such a position that main burnerignition will occur with minimum delay with a low pilot flame just sufficient to open the main gas valve.23. If the pilot fails to light when the control circuits are closed it may require manual resetting. Always waitat least 5 minutes before resetting the system. To reset turn the main switch to pump #1/only, then backto burner #2. Repeat if needed.OPERATING INSTRUCTIONSFollowing delivery and installation of your Delco pressure washer, inspect the unit for shipping damage andfollow these directions.1. Observe all danger, warning, and caution statements.2. Squeeze the trigger. Turn the control switch to position one (cold water wash). Allow the air to purgefrom the system. Check the system for leaks.3. Point the wand toward the floor. Flush out the system.4. Turn the machine to the "OFF" position.5. Install the nozzle onto the wand.6. Turn the control switch to position one to establish the water flow. Turn the control switch to position two(hot water wash). The burner should automatically come on. The burner should light in approxmatelyone to thirty seconds. If delay is longer adjust the pilot and check spark gap (7/64").NOTE: When the trigger gun is released for more than 4.5 minutes the machine will shut off. Youmust turn the control switch to the "OFF" position then "ON" to restart. The timer is to protect thepump and is not intended to take the place of the main "ON-OFF" switch.WARNING: If the water should stop flowing from the gun, turn the unit off immediately and contact anauthorized Delco service person.7. Point the wand toward the object to be cleaned and proceed.8. For chemically enhanced cleaning, place the chemical feed line in liquid detergent. Open the meteringvalve. Dial the metering valve to obtain the desired chemical concentration. Close the metering valvefor rinsing.DANGER: The detergent level should never fall below the chemical line strainer. If you shoulddiscover this condition, immediately turn the metering valve off. Air introduced into thesystem will cause pump damage and create steam space if the burner is on which maylead to a steam explosion.