43Programming Procedure[Data Verifier] Scan “Program” to enter the programming mode. Scan “Verifier Control” and set bar code symbology to“08” (Interleaved 2 of 5). Scan “Identified Data Length” and set the length to“16”. Scan “1st Identified Character” and set the identifiedposition to “00”, then set the identified character to“39” (Hex Code of 9).[Data Formatter] Scan “Formatter Control” and set bar codesymbology to “08” . Scan 1st Insertion” and set the identified position to“06” , then inserted characters to “09” (Hex Code ofTAB), “53” (Hex Code of S), “4E” (Hex Code of N). Scan “2nd Insertion” and set the identified position to“12” , then inserted character to “09” . In the final,you must scan “FIN” (Finish) code to terminate thisselection. Scan “3rd Insertion” and set the identified position to“16” , then inserted character to “09” . In the final,you must scan “FIN” (Finish) code to terminate thisselection.[Data Replacer] Scan “Replacer Control” and set bar code symbologyto “08” . Scan “1st Replacement” and set the identifiedposition to “00” , then replaced character to “41”(Hex Code of A).[Data Organizer] Scan “Organizer Control” and set bar code symbologyto “08” . Scan “1st Organization” and set the identifiedposition to “16” , then set the data transmission to“0” (forward). Scan “2nd Organization” and set the identifiedposition to “17” , then set the data transmission to“1” (backward). Scan “END” (Exit) to terminate the programming.[Important Notice]Please note that Condensed DataWizard will follow thepreset working flow as below:Verifier Formatter Replacer OrganizerSo when you set the identified position in DataOrganizer, you must consider the inserted data whichyou already set via Data Formatter.