F14 AND 48000 Series Service and Installation Manual3For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.comMODEL NUMBER OF NUMBER OF SHIPNUMBER OPENINGS* GAS BURNERS BTU WEIGHTGas with single tank — wet operation onlyF14GW232 2 1 20000 256 lbs/116 kgF14GW348 3 1 20000 326 lbs/148 kgF14GW460 4 1 20000 396 lbs/180 kgF14GW572 5 2 40000 456 lbs/207 kgF14GW688 6 2 40000 536 lbs/243 kg*Each opening measures 11.87” x 19.87” (30.2cm x 50.5cm).MODEL SHIPNUMBER VOLTAGE AMPS WEIGHTElectric with individual wells — wet or dry operation48334 120/208 17.0/11.0 179 lbs/81 kg48348 208/230 15.0/16.0 252 lbs/114 kg48362 208/230 20.0/22.0 326 lbs/148 kg48376 208/230 24.0/27.0 400 lbs/181 kgSPECIFICATIONSMODEL NUMBER OF AMPS SHIPNUMBER OPENINGS 208/230 WEIGHTElectric with individual wells — wet or dry operationF14EI232 2 10.0/11.0 216 lbs/98 kgF14EI348 3 15.0/16.0 296 lbs/134 kgF14EI460 4 20.0/22.0 376 lbs/170 kgF14EI572 5 24.0/27.0 456 lbs/207 kgF14EI688 6 29.0/32.0 536 lbs/243 kgElectrical connections are 208/230 volt, 60 cycle, single phase.Each opening measures 11.87” x 19.87” (30.2cm x 50.5cm).Electric with single tank — wet operation onlyF14EW232 2 21.0/24.0 316 lbs/143 kgF14EW348 3 21.0/24.0 440 lbs/199 kgF14EW460 4 21.0/24.0 500 lbs/227 kgF14EW572 5 42.0/48.0 560 lbs/254 kgF14EW688 6 42.0/48.0 660 lbs/299 kgElectrical connections are 120/240 volt, or optional 120/208 volt.(120 volt circuit is required for the low water cutoff.)INSTALLATION: F14EI & F14EW SERIES (ELECTRIC)Installation should only be done by personnelcertified and licensed to install and maintainelectrical appliances.LocationDo not install the hot food table near any combustible objects orsurfaces affected by heat or moisture.LevelingThis unit must be level, both front and back and left to right, inorder to maintain an equal water depth throughout the wells.PlumbingHot water supply connection is provided 36” (91.4cm) above thefloor, 3.12” (7.9cm) from the front left end at the rear of the unit.You must supply the required 1/2” NPT connection.A waste connection is provided 25” (63.5cm) above the floor, 7.5”(19cm) from the right end. You must supply the required 1” NPTconnection.Electrical connectionConnections must be made in accordance with allapplicable local codes and/or the National ElectricalCode. Refer to the wiring diagrams on page 10.INSTALLATION: 48300 SERIES (ELECTRIC)Installation should only be done by personnelcertified and licensed to install and maintainelectrical appliances.LocationDo not install the hot food table near any combustible objects orsurfaces affected by heat or moisture.LevelingThis unit must be level, both front and back and left to right, inorder to maintain an equal water depth throughout the wells.PlumbingA waste connection is provided 26.5” (67.3cm) above the floor,5.25” (13.3cm) from the right end. You must supply the required1” NPT connection.Electrical connectionConnections must be made in accordance with allapplicable local codes and/or the National ElectricalCode. Refer to the wiring diagrams on page 10.