6000XL Series Service and Installation Manual17For customer service, call (800) 733-8829, (800) 733-8821, Fax (888) 779-2040, www.delfield.comDelfield™ ®Standard Labor Guidelines To Repair Or Replace Parts On Delfield EquipmentAdvice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.• A maximum of 1-hour is allowed to diagnose a defective component.• A maximum of 1-hour is allowed for retrieval of parts not in stock.• A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.• Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/orcorrecting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service WorkAuthorization from Delfield. You must submit the number with the service claim.LABOR OF 1-HOUR IS ALLOWED TO REPLACE:• Thermostat • Door Jamb Switch• Evaporator/Condenser Fan Motor and Blade • Solenoid Coil• Hi-limit/Thermal Protector Switch • Fan Delay/Defrost Termination Switch• Compressor Start Components and Overload Protector • Door Hinges, Locks, and Gaskets• Condensate Element • ThermometerLABOR OF 2 HOURS TO REPLACE:• Defrost Element • Solenoid Valve• Locate/Repair LeakLABOR OF 3 HOURS TO REPLACE:• Condenser or Evaporator Coil• Expansion ValveLABOR OF 4 HOURS TO REPLACE• CompressorThis includes recovery of refrigerant and leak check.$55.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings,solder, brazing rod, nitrogen, or similar fees.)REFRIGERANTS• R404A A maximum of $15.00/lb. or $1.00/oz. will be reimbursed.