Compact Refrigerators and Freezers Service and Installation Manual5For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com400 & 4000 Series caster installationCarefully place the unit on its back (see illustration at right).Remove legs by unscrewing them in a counter clockwise direction.Located on each end of the compressor channel are 4 hex head screws, for a total of8 screws. Remove them. 8 additional screws are provided with your casters.Place a locking plate caster over one of the front holes, matching the 4 mountingholes to the pre-drilled holes in the underside of the unit. Insert 4 hex head screwsand tighten. Repeat with the other locking front casters.Repeat step 4 with the non-locking casters in the rear of the unit.Carefully lift the unit upright.After installing casters, the unit must stand upright for twenty-four (24)hours before being powered up to assure oil return to the compressorsump.NOTE: Check parts list for correct caster application.1.2.3.4.5.6.Plate CastersW/LocksPlate CastersW/O Locks#14 x .75" Hex HeadScrews #932-1116Plate caster installation, 400 & 4000 Series.Caster Installation - 400 & 4000 SeriesCaster/Leg Mounting Detail2”, 3” and 5” Caster and Leg Mounting DetailA universal bolt hole pattern is provided on the bottom of the cabinet. It will accommodate any leg or caster. Simply line up the plateholes with the corresponding cabinet holes.2.38”3.40”1.75”2.82”0.94”2.14”NOTE:If hole pattern on caster/legmatches the one above mountin inner set of holes.2” Caster - 3234148NOTE:If hole pattern on caster/legmatches the one above mountin middle set of holes.3” Caster - 32340245” Caster - 3234161NOTE:If hole pattern on caster/leg matches the one abovemount in outer set of holes.6” Leg - 3234569WARNING