24 About Your SystemE1811 HDD ## Rbld Abrt The specified hard drive hasexperienced a rebuild abort.See "Troubleshooting a HardDrive" on page 124. If theproblem persists, see your RAIDdocumentation.E1812 HDD ## Removed The specified hard drive has beenremoved from the system.Information only.E1913 CPU & FirmwareMismatchThe BMC firmware does notsupport the CPU.Update to the latest BMCfirmware. See the BMC User’sGuide for more information onsetup and use of BMC.E1A11 PCI Rsr Config PCI risers are not configuredcorrectly; some invalidconfigurations may prevent thesystem from powering on.See "Expansion-Card RiserBoards" on page 98.E1A12 PCI Rsr Missing One or all of the PCI risers ismissing, preventing the systemfrom powering on.Information only.E1A14 SAS Cable A SAS cable A is missing or bad. Reseat the cable. If problempersists, replace cable. See "SASController Daughter Card" onpage 69.E1A15 SAS Cable B SAS cable B is missing or bad. Reseat the cable. If problempersists, replace cable. See "SASController Daughter Card" onpage 69.E2010 No Memory No memory is installed in thesystem.Install memory. See "InstallingMemory Modules" on page 90.E2011 Mem Config Err Memory detected, but is notconfigurable. Error detectedduring memory configuration.See "Troubleshooting SystemMemory" on page 120.E2012 Unusable Memory Memory is configured, but notusable. Memory subsystemfailure.See "Troubleshooting SystemMemory" on page 120.E2013 Shadow BIOS Fail The system BIOS failed to copyits flash image into memory.See "Troubleshooting SystemMemory" on page 120.E2014 CMOS Fail CMOS failure. CMOS RAM notfunctioning properly.See "Getting Help" on page 147.E2015 DMA Controller DMA controller failure. See "Getting Help" on page 147.Table 1-6. LCD Status Messages (continued)Code Text Causes Corrective ActionsBook.book Page 24 Friday, February 3, 2006 11:09 AM