Using the System Setup Program 49NOTE: When Flow Control is set to Software, the Hyper Terminal on remote side isdiscontinued by pressing . But the is also the Setup Key Strokefor setting onboard NIC PXE Option ROM Configuration. Therefore, we suggestusers change to in PXE OPROM Configuration in order to avoidthat the Hyper Terminal on remote side is discontinued when pressing .IPMI ConfigurationRedirection After BIOS POST(Always default)Selects the settings for the redirection. This itemdisappears when Remote Access is disabled:• Disabled: turns off the redirection after POST.• Boot Loader: redirection is active during POST andboot loader.• Always: redirection is always active. (Someoperating systems may not work if set to Always)Terminal Type(VT100 default)Selects the target terminal type. This item disappearswhen Remote Access is disabled.VT-UTF8 Combo KeySupport (Enabled default)Enables or disables VT-UTF8 combination keysupport for ANSI/VT100 terminals. This itemdisappears when Remote Access is disabled.Terminal Display Mode(Normal mode default)Selects Terminal Display Mode.Options:• Normal Mode• Recorder ModeOption DescriptionStatus Of BMC Displays BMC status.BMC Firmware Revision Displays BMC Firmware Revision.View BMC SystemEvent LogSelecting this option and pressing Enter, displays:Total Number Of Entries, SEL Entry Number,SEL Record ID, SEL Record Type,Event Time Stamp, Generator ID, Event MessageFormat Version, Event Sensor Type, Event SensorNumber, Event Dir Type, and Event Data.Option Description