DellPowerEdge T610 Technical Guide 41Mixed SATA + SASMin 2xSAS + 1xSATA2.5” = Max 2xSAS +6xSATA3.5” = Max 2xSAS +6xSATAConfigurationTypeConfiguration Description Min HDD Max HDDSAS + SATA—No RAID 8 MSS-X Integrated SAS/SATA NoRAID (SAS 6/iR, PERC H200)2.5" = 33.5" = 32.5"=63.5"=6SAS + SATA—RAID9 MSSR1R1-XIntegrated SAS/SATA RAID1/RAID 1 (SAS 6/iR, PERC6/i, PERC H200, PERC H700)2.5"=2+23.5"=2+22.5" = 2+23.5" = 2+211 MSSR1R5-XIntegrated SAS/SATA RAID1/RAID 5 (PERC 6/i, PERCH700)2.5"=2+33.5"=2+32.5" = 2+63.5" = 2+6Mixed SSD + SASMin 2xSSD + 1xSAS2.5” = Max 2xSSD +6xSASConfigurationTypeConfiguration Description Min HDD Max HDDSSD + SAS—RAID15 MSSR1R5-X Integrated SSD/SAS RAID1/RAID 5 (PERC 6/i, PERCH700)2.5"=2+33.5"=N/A2.5"=2+63.5"=N/A12.4 Storage Controllers12.4.1 SAS 6/iRThe T610 internal SAS 6/iR HBA is an expansion card that installs into the dedicated internal storageslot. It incorporates two four-channel SAS IOCs for connection to SAS or SATA hard disk drives. It isdesigned in a form factor that allows the same card to be used in the PowerEdge T610 andPowerEdge T610.12.4.2 PERC 6/iIf you want an internal RAID solution, select the PERC 6/i or PERC H700. The PERC 6/i uses the LSI1078 ROC (RAID on Chip) processor with a PCI Express host interface and DDR2 memory, and it installsinto the dedicated internal storage slot. A battery is also available for backup.12.4.3 PERC H200The H200 SAS HBA is an expansion card that installs into the dedicated internal storage slot. Itincorporates two four-channel 6 Gb/s SAS IOCs for connection to SAS hard disk drives. It is designedin a form factor that allows the same card to be used in other 11G 2U rack-form factor platforms.