23 PowerEdge VRTX Technical GuideAttribute ValueMax output current 108.0 AmpsInput voltage range 90–264V AC, 47–63HzIin (100–240V AC) for rating on safety label 12.0 Amps–6.5 AmpsInitial in-rush current 55 Amps (peak)Secondary in-rush current 25 Amps (peak)1100W PSU efficiencyTable 8.10% load 20% load 50% load 100% loadPower supply efficiency at 115VAC 87% 91% 92.5% 90%Power supply efficiency at 230VAC 89% 93% 94.5% 92%ThermalFour blower modules with dual blowers are located on the back of the VRTX chassis. Six fans arelocated between the SAS backplane and expander cards and the system planar components. Youcan check fan status using the control panel LCD or the systems management interfaces.In chassis standby mode, all components are unpowered except the CMC, the LCD control panel,and two fans for cooling the CMC components. For chassis standby mode, the system needs to runone or two fans at low RPM to ensure that the CMCs are properly cooled.AcousticsPowerEdge VRTX has been consciously designed with an open office layout in mind, including itsacoustical design. Acoustic intensity has been minimized as a function of delivered airflow, andtones (buzzes, hums, whistles) have been removed. The result is a smooth sound generally maskedby that of normal office air conditioning or conference room conversations. Certain configurationsand utilizations are quieter than others — if your environment is acoustically sensitive, Dell can helpyou choose the right configuration.