Specifications TP02G-AS1Vibration 5Hz f≦ <9Hz = Continuous: 1.75mm / Occasional: 3.5mm9Hz f 150Hz = Continuous: 0.5g / Occasional: 1.0g≦ ≦Shock 15g peak, 11ms duration, half-sine, three shocks in each direction per axis,on 3 mutually perpendicular axes (total of 18 shocks)Radiated emission CISPR11, Class AElectrostatic discharge immunity EN61000-4-2Radiated immunity EN61000-4-3Electrical fast transient EN61000-4-4Altitude 0 ~ 2000 metersWeight/dimensions 0.24kg; 147 × 97 × 35.5mm (Width(W) × Height(H) × Deep(D))Cooling method Natural air cooling Password Function1. If the user forgot the password, the password can be cleared by using the following code: 8888. Thisuniversal code will clear the password and all TP02 series internal programs. The TP02 series will be reset tothe factory settings by using this code also. Please pay close attention when using it.2. The password can be the alphabet from A to Z or the number from 0 to 9. But it must use the function keys F0~ F9 to input the password characters. Please refer to the following table.F0: scrolls in a loop as follows 0→A→B→C→D→E→F→0.F1: scrolls in a loop as follows 1→G→H→I→J→K→1.F2: scrolls in a loop as follows 2→L→M→N→O→P→2.F3: scrolls in a loop as follows 3→Q→R→S→T→U→ V→3.F4: scrolls in a loop as follows 4→W→X→Y→Z→4.F5: It just can be used to be constant 5.F6: It just can be used to be constant 6.F7: It just can be used to be constant 7.F8: It just can be used to be constant 8.F9: It just can be used to be constant 9. Hardware OperationWhen the user wants to startup TP02 series, a 24V DC power is needed. After applying 24V DC power to TP02series, it will enter into the startup display and then enter the user-designed program. Pressing Esc key andholding on for 5 seconds can return to system menu. There are five selections in the system menu and aredescribed below.Selections ExplanationDownloadprogramUse the connection cable (UC-PRG020-12A (2M)) to connect the TP02 serial communication port RS-232to a PC. Then use the TPEditor/DIAScreen software to download an application program to TP02.UploadprogramUse the connection cable (UC-PRG020-12A (2M)) to connect the TP02 serial communication port RS-232to a PC. Then use the TPEditor/DIAScreen software to upload an application program from TP02.CopyprogramTransfer a program between two TP02 units.1: transmit programs; 2: receive programs.When transmit programs and data between two TP02 units. Set one TP02 to “Receive Program” modeand the other TP02 to “Transmit Program” mode. Please use twisted pair wires to connect the two unitsvia the RS-485 ports.TP02settingsThere are 8 items that used to modify TP02 system settings:1. Communication protocol: Setting the address of TP02, the control port of PLC, and the communication