Delta TP04G-AS2 Instruction Sheet
Also see for TP04G-AS2: Instruction sheetInstruction sheetInstruction sheet
http://www.delta.com.tw/industrialautomation/2006-0 7-185011627101-4 GE1TP04G-AS2 Terminal Panels SeriesInstruction Sheet1 WARNINGPlease carefully read this instruction before using the TP04G.DANGER! DC input power must be OFF before any maintenance. Do not insert or remove wires andconnectors while power is applied to the circuit. Only the qualified technicians are allowed to perform themaintenance.The TP04G display panel is waterproof. But please prevent grease, corrosive liquids and sharp objects fromcontacting the TP04G.DANGER! The TP04G requires 24VDC input power. The 24VDC input power should not be connected tothe RS-485 communication port. The unit may be destroyed or can’t be repaired if the input power isimproperly applied. Please always check the correctly input power wiring before apply power.DANGER! An electrical charge will remain on the DC-link capacitors for 1 minute after power OFF. Thisresidual power may be hazardous and the TP04G should not be worked on until this charge has dissipated.To prevent injury, do not conduct any wiring or investigation on the TP04G until 1 minute after power hasbeen removed.CAUTION! Always ground the TP04G by using the grounding terminal. Not only this acts as a safety, butalso filter out electrical noise. The ground method must comply with the laws of the country where the unit isto be installed.CAUTION! TP04G may be damaged if the fixed support (shipped with the pack) is adjusted too tight.Battery replacement: please use UL component type: CR2030 lithium battery which battery life is 1200hours after power loss. (NOTE: RTC should be reset after changing battery).2 INTRODUCTION2.1 Model Explanationz Thank you for choosing DELTA TP Series. TP04G-AS2 has the features of high resolution 128*64 to display8*4 Chinese characters max, and Multilanguage support.z Built-in two communication ports so that RS-232 and RS-485/RS-422 can be used simultaneously.z Built-in RTC and communication/alarm indication LED.z Possess extension slot for program copy card to copy settings and programs rapidly and save downloadtime.z Built-in various objects to meet your requirements. NameplateMODEL :POWER INPUT :TP04GAS2W6050004VX.XXTP04G-AS224Vdc 3.5WDELTA ELECTRONICS, INC MADE IN XXXXXXXProduction modelPower input spec.Barcode andserial numberVersionNote: The words of “MADE IN XXXXX” will be different due to the manufacturing location. Model and Serial Number ExplanationModel Explanation TP 04 G AS 2-RS-232/RS-422/RS-485 interfaceReservedT: Text modeG: Graphic modeLCD Spec.Series nameSerial Number Explanation TP04GAS 2 W 6 05 0004Production serial numberProduction weeksProduction year(2006)Production plant(W:Wuijang)VersionProduction model2.2 OutlineLCMDisplay Area RS-485/RS-422Indication LEDEscape/ExitShift KeyArrow keysFunction KeysEnter keyRS-232 Indication LEDAlarm Indication LED2.3 Panel Function ExplanationPANEL COMPONENT EXPLANATIONAlarm Indication LED (RED)Status 1: When power is on, LED will blink slowly for three times.Status 2: When there is an abnormal situation, LED will blink quickly along withan alarm sound.RS-232 Indication LED(Yellow) LED will blink when transmits program and communicates via RS-232.RS-485/RS-422 IndicationLED (Green) LED will blink when communicates via RS-485/RS-422.LCM display Area Liquid Crystal Module display area used to display current program state.Escape/Exit Used to cancel an incorrect input, or to Exit a programming step.Arrow KeysUP/Pg Up: Used to increase the value or move up one page.Pg Dn/DOWN: Used to decrease the value or move down one page.Left: Left direction key (move curser to left).Right: Right direction key (move cursor to right).Shift Key Used to select keys F5, F6, F7, F8, F9.Enter key Used to input a value or accept a programming command.Function KeysF0/F5: used to be constant 0 (F0) and 5 (Shift+F0) when it is in the systemmenu, user can use it to define functions separately when they are inuser page.F1/F6: used to be constant 1 (F1) and 6 (Shift+F1) when it is in the systemmenu, user can use it to define functions separately when they are inuser page.F2/F7: used to be constant 2 (F2) and 7 (Shift+F2) when it is in the systemmenu, user can use it to define functions separately when they are inuser page.F3/F8: used to be constant 3 (F3) and 8 (Shift+F3) when it is in the systemmenu, user can use it to define functions separately when they are inuser page.F4/F9: used to be constant 4 (F4) and 9 (Shift+F4) when it is in the systemmenu, user can use it to define functions separately when they are inuser page.2.4 Back PanelBATTERYSWITCH ORRS-485/4225-PIN terminals: / Wire gauge: 12-24 AWG / Torque: 4.5 lb.-inch2.5 DimensionFront panel (unit: mm [inch]) Right side diagram (unit: mm [inch])97.00[3.82]147.00 [5.79]85.00[3.35]Back panel Mounting dimension (unit: mm [inch])Thickness Range 0.5~9mm135~136.5[5.31~5.37]85[3.35]Vertical view (Unit: mm)2.6 InstallationOne easy way is insert TP04G to the opening hole of panel and tight up the screws. However, if a firmmounting TP04G to the panel is needed, please use the fixed support accessory which is packed together withTP04G, then infix the fixed support in the back and tight up the screws. (NOTE: the flat surface should be a Type 4"Indoor Use Only" enclosure or equivalent.)If fixed support is not installed well, Delta will not guarantee the waterproof function. If you turn the screwexceeds torque: 4-5(kg-cm), TP04G could be damaged.(Note:the flat surface shoud be a Type 4 “Indoor Use Only” enclosure or equivalent.)Please leave sufficient space (more than 50mm) around the unit for heat dissipation.Thickness:0.5~9.0mm50mm50mmPlease leave sufficient space (more than 50mm)around the unit for heat dissipation.3 SPECIFICATION3.1 Electrical SpecificationITEM TP04G-AS2Function Key/Digital Key F0~F4, ESC, SHIFT, ENTER and ARROW keysExternal Input Power 24V (-15%-20%) 3.5W Max.Memory Capacity 256K ByteCPU Hitachi HD64F3064FRAM of System 32K ByteCommunication Interface COM1: RS232; COM2: RS485/RS422Waterproof Class of Front Panel IP65/NEMA4/UL Type 4 (indoor use)Environment Condition 0~50℃, relative humidity 20-90% RH (non-condensing)Storage Temperature for Hardware -20~60℃Vibration 1.0G, 10-150Hz, X, Y, Z three directions and 10 sweep cycles per axisShock 15G, 11ms, from X, Y, Z three directions and three times for eachdirectionRadiated Emission CISPR22, Class AElectrostatic Discharge Immunity EN61000-4-2/1995Radiated Immunity EN61000-4-31995Electrical Fast Transient EN61000-4-4/1995Weight/Dimension 0.24kg/147×97×35.5mm (Width × Height × Deep)Cooling Method Natural Air CoolingPollution Degree 2Altitude 2000 m or lower |
Related manuals for Delta TP04G-AS2
Delta TP04G-AS2 Instruction Sheet
Delta TP04G Instruction Sheet
Delta TP04G-AL Instruction Sheet
Delta TP04G-BL-CU Instruction Sheet
Delta TP04 Series Instruction Sheet
Delta TP Series Instruction Sheet
Delta DOP-B08 Instruction Sheet
Delta DOP-B03 Instruction Sheet
Delta B10S615 Instruction Sheet
Delta DOP-107DV Instruction Sheet
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine