DenMat PeriOptix MicroLine Mini Directions For Use Manual
Also see for PeriOptix MicroLine Mini: Directions for use
Operating Instructions1. Charging batteries.a. Plug the power adapter (1) into a power outlet and connect to battery charger unit (2). A single green light will indicatepower to the charger.b. Slide the battery from the power pack (3) into the charger unit (2) with connectors facing the pins. Make sure thebattery is lying flat on the charger base prior tosliding it forward to engage charger terminals.Note: Pushing the battery forward without keeping it flat may damage charger pins.c. When the battery is inserted into the charger, the charger status light turns from green to red to indicate that charginghas begun.d. Once the battery is fully charged, the light will return to green.2. Mounting the Light on to Loupes.Attach the lamphead to loupes using the supplied mount and hardware.Flip style loupes (PeriOptix,® Surgitel,® Orascoptic,® etc.)Slide clip onto front of interpupillary cross bar of loupes, with one circular cut-out on top and one cut-out on the bottomof the cross bar. The clip should securely snap into place.Through-The-Lens (TTL) solid bridge mountLoosen the thumb nut on bridge clamp, opening the two halves wide enough to engage the top and bottom of framenose bridge. Attach the clamp to the bridge so that the grooves in the jaws grab the top and bottom edges of thebridge and then tighten nut.Universal Mount attachment to eyeglass framesOpen the clip and slide down over the top of the nose bridge. The padded arms of theclip should grasp each side of the eyeglass lenses. Tighten thumb screw to secure clip to frame.3. Clip the power pack to your waist band or pocket.a. Attach the lamp cord to the loupe frames with the small elastic strap.b. Use the shirt clip on the lamp cord to position the cord on your shirt or lab coat as desired.c. Remove battery from charger unit and slide into the power pack. The battery should snap into place.4. Turn on lamp using on/off button.a. The intensity control knob will adjust lamp intensity.5. Adjust the direction of the LED beam.a. To adjust the tension of the lamp head position, use the supplied phillips screwdriver to tighten or loosen the twosmall link screws as needed.6. Precautions.a. Equipment in medical environments , including this product, can produce electromagnetic interference (EMI).These effects are prevented by the use of equipment with EMI characteristics below proven recognized limits for thespecified operating environment. In the event of suspected electrical interference with other equipment, cycle the poweron the Solaris to remedy the EMI effect.denmat.comOperating Environment:• 10° - 30°C (50° - 86°F)• 95% or less relative humidity• 70kPa – 106kPaTransport/Storage:• 0° - 40°C (32° - 104°F)• 95% or less relative humidity• 70kPa – 106kPaTechnical Data:Headlight System: Internally powered by 7.2Vdc, 2500 mAHrechargeable Lithium-ion battery packSolaris (LED2-BP): 730mAMini (LED4-BP): 540mAPower Supply: 100 – 240V~, 50 – 60 Hz, 0.5ADefinition of SymbolsUser Must Read Instruction ManualClass II Equipment Alternating Current Direct CurrentEuropean Conformity For Indoor Use OnlyRecycle for Lithium-ion Recycle or Dispose ofProperly Caution, Consult Documents |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine