12100165SERVICEPROCEDUREContinued21. Connect motor wires asfollows (see Figure 6,page 10):• white wire—to terminalboard.Note: Attach toempty connector on whitewire side of terminalboard.• red wire—to terminalboard.Note: Attach toempty connector on blackwire side of terminalboard.• blue wire—to thermalswitch wire• blue wire—to solenoidvalve• green wire—to groundingscrew on shell22. Replace side cover.23. Replace fan guard.ModelInput Rating (kJ/Hr) (BTU/Hr)FuelFuel ConsumptionGallons/HourPounds/HourSupply Pressure To RegulatorMinimum (for purposes ofinput adjustment)MaximumRegulator Outlet PressureMotorElectric InputAmperageWeightHeaterShippingSize - L x W x HHeaterCartonRCLP375 and BCLP375168.800 to 332.325 (160,000 to 315,000)Propane Vapor Only6,8 l/h min./13,6 l/h max.(1.8 Minimum/3.6 Maximum)3,35kg/h min./ 6,85 kg/h max.(7.4 Minimum/15.1 Maximum)172 kPa (25 psig)1379 kPa (200 psig )48 - 138 kPa (7-20 psig)1700 RPM120 V/60 Hz3.018, 1 kg (40 lbs.)21,8 kg (48 lbs.)89 cm x 33 cm x 51 cm (35 in. x 13 in. x 20 in.)94 cm x 40,5 cm x 53,5 cm (37 in. x 16 in. x 21in.)SPECIFICATIONS