10103547PROPANE/LP GAS HEATER10,000 AND 6,000 BTU/HRGRH/OV 008BAD PILOT/LPTO TURN OFF GASTO APPLIANCE1. Remove front panel (see Figure 10,page 7).2. Follow steps 1 through 5 under Light-ing Instructions.3. With control knob pressed in, strikematch. Hold match to pilot until pi-lot lights.4. Keep control knob pressed in for 30seconds after pilot is lit. After 30 sec-onds, release control knob.5. Replace front panel.INSPECTINGBURNERCheck pilot flame pattern and burner flamepattern often.PILOT FLAME PATTERNFigure 18 shows a correct pilot flame pat-tern. Figure 19 shows an incorrect pilotflame pattern. The incorrect pilot flame isnot touching the thermocouple. This willcause the thermocouple to cool. When thethermocouple cools, the heater will shutdown.GRH/OV 007GOOD PILOT/LPThermocouplePilot BurnerThermocouplePilot BurnerFigure 19 - Incorrect Pilot Flame PatternIf pilot flame pattern is incorrect, as shownin Figure 19• turn heater off (see To Turn Off Gas toAppliance)• see Troubleshooting, pages 12 through14Figure 18 - Correct Pilot Flame Pattern4. Wait five (5) minutes to clear out anygas. Then smell for gas, includingnear the floor. If you smell gas,STOP! Follow “B” in the safety in-formation at the top of page 16. If youdon’t smell gas, go to the next step.5. Press in control knob and turn coun-terclockwise C-clockwise to the PILOTposition. Keep control knob pressedin for five (5) seconds (see Figure 16).Note: You may be running thisheater for the first time after hook-ing up to gas supply. If so, the con-trol knob may need to be pressed infor 30 seconds. This will allow air tobleed from the gas system.• If control knob does not pop upwhen released, contact a qualifiedservice person or gas supplier forrepairs.6. With control knob pressed in, pushdown and release ignitor button. Thiswill light pilot. The pilot is attachedto the front of burner. The pilot canbe seen through the glass panel. Ifneeded, keep pressing ignitor buttonuntil pilot lights.Note: If pilot does not stay lit, referto Troubleshooting, pages 12 through14. Also contact a qualified serviceOPERATINGHEATERContinuedCAUTION: Do not try to ad-just heating levels by using themanual shutoff valve.Thermocouple Pilot BurnerFigure 17 - PilotIgnitor ElectrodeLIGHTINGINSTRUCTIONS1. STOP! Read the safety informationpage 9, column 3.2. Make sure manual shutoff valve isfully open.3. Turn control knob clockwise Clockwiseto the OFF position.OFFHIGHPILOTLOWIGNITORFigure 16 - Control Knob In The OFFPositionIgnitor Button Control Knobperson or gas supplier for repairs.Until repairs are made, light pilotwith match. To light pilot with match,see Manual Lighting Procedure.7. Keep control knob pressed in for 30seconds after lighting pilot. After 30seconds, release control knob.Note: If pilot goes out, repeat steps3 through 7.8. Turn control knob counterclockwiseC-clockwise to the HIGH position. Themain burner should light. Set controlknob to any heat level between HIGHand LOW. To turn control knob fromHIGH to a lower setting, press in thecontrol knob and turn counterclock-wise C-clockwise .Note: Both HIGH and LOW arelocked positions. You must press incontrol knob before turning it fromthese positions.Shutting Off Heater1. Turn control knob clockwise Clockwiseto the PILOT position.2. Press in control knob and turn clock-wise Clockwise to the OFF position.Shutting Off Burner Only (pilotstays lit)1. Turn control knob clockwise Clockwiseto the PILOT position.MANUAL LIGHTINGPROCEDURE