www.desatech.com104415-01M 29TROUBLESHOOTINGWARNING: Turn off and unplug heater and let cool before servicing.Only a qualified service person should service and repair heater.CAUTION: Never use a wire, needle or similar object to cleanODS/pilot. This can damage ODS/pilot unit.Note: All troubleshooting items are listed in order of operation.POSSIBLE CAUSE1. Ignitor electrode not con-nected to ignitor cable2. Ignitor cable pinched or wet3. Piezo ignitor nut is loose4. Broken ignitor cable5. Bad piezo ignitor6. Ignitor electrode positionedwrong7. Ignitor electrode broken1. Gas supply turned off or equip-ment shutoff valve closed2. Control knob not in PILOTposition3. Control knob not pressed inwhile in PILOT position4. Air in gas lines when in-stalled5. Depleted gas supply (pro-pane/LP only)6. ODS/pilot is clogged7. Gas regulator setting is notcorrectOBSERVED PROBLEMWhen ignitor button is pressed,there is no spark at ODS/pilotWhen ignitor button is pressed,there is spark at ODS/pilot butno ignitionREMEDY1. Reconnect ignitor cable2. Free ignitor cable if pinchedby any metal or tubing. Keepignitor cable dry3. Tighten nut holding piezo ig-nitor to base panel of log set. Nutis located behind base panel4. Replace ignitor cable5. Replace piezo ignitor6. Replace pilot assembly7. Replace pilot assembly1. Turn on gas supply or openequipment shutoff valve2. Turn control knob to PILOTposition3. Press in control knob while inPILOT position4. Continue holding down con-trol knob. Repeat igniting op-eration until air is removed5. Contact local propane/LP gascompany6. Clean ODS/pilot (see Cleaningand Maintenance, page 27) orreplace ODS/pilot assembly7. Replace gas regulator