10887116For more information, visit www.desatech.comFor more information, visit www.desatech.comWIRING DIAGRAMSSPECIFICATIONSWIRING DIAGRAMSPower Plug120V/60HzBlueBlueWhiteWhitePhotocellGreenGreenRedBlackYellowYellowMotorIgnitorIgnition Control AssemblyPhotocellPhotocellIgnitorMotor ReturnAC Neutral (L2)120V (L1)IgnitorMotorFigure 34 - Wiring Diagram without Thermostat (40/55/60/70/110/115/150/155/165 Models)Model Size 40 55/60 70 110/115 150/155 165 200Output Rating (Btu/Hr) 40,000 55,000 70,000 110,000 150,000 165,000 200,000and 60,000 and 115,000 and 155,000Fuel Use only kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels*Fuel Tank Capacity(U.S. Gal./Liters) 3/11.3 5/18.9 5/18.9 9/34 13.5/51 13.5/51 13.5/51Fuel Consumption(Gal. Per Hr/Liters Per Hr) .3/1.14 .44/1.67 .52/1.97 .85/3.00 1.14/4.31 1.2/4.54 1.4/5.3Pump Pressure (psi) 3.0 3.4 4.7 5.3 5.4 5.6 6.2Electric Requirements 120 V/60 HZ (Same All Models)Amperage (Normal Run) 2.0 2.0 2.8 3.6 3.6 3.6 3.6Motor RPM 1725 1725 3440 3400 3400 3400 3400Hot Air Output (CFM) 170 180 360 490 550 575 600Motor HP 1/15 1/15 1/8 1/5 1/5 1/5 1/4Shipping Weight 32/14.5 33/15 35/15.9 54/24.5 63/28.6 65/29.5 77/35(Approximate Pounds/Kilograms)Heater Weight without Fuel 28/12.7 29/13.1 31/14 46/21 54/24.5 55/25 66/30(Approximate Pounds/Kilograms)* Use of #2 diesel & fuel oil will result in noticeable odor and could require additional fuel filter maintenance. Use in extreme coldtemperatures may require nontoxic anti-icer additives.SPECIFICATIONS