110021-01CFor more information, visit www.desatech.comFor more information, visit www.desatech.com28SPECIFICATIONS24" Remote-Ready 30" Remote-ReadyBtu (Variable) 10,000/40,000 10,000/40,000 10,000/40,000 10,000/40,000Type Gas Propane/LP Natural Propane/LP NaturalIgnition Piezo Piezo Piezo PiezoManifold Pressure 8.0" W.C. 3.0" W.C. 8.0" W.C. 3.0" W.C.Inlet Gas Pressure(in. of water)Maximum 14" 10.5" 14" 10.5"Minimum* 11" 5" 11" 5"Shipping Weight 30 lbs. 30 lbs. 34 lbs. 34 lbs.Certified Standards Z21.11.2-2000 Z21.11.2-2000 Z21.11.2-2000 Z21.11.2-2000Z21.60-1996 Z21.60-1996 Z21.60-1996 Z21.60-1996CGA2.26-M96 CGA2.26-M96 CGA2.26-M96 CGA2.26-M96* For purpose of input adjustmentSPECIFICATIONSWIRING DIAGRAM (REMOTE-READY MODELS ONLY)SERVICE HINTSTECHNICAL SERVICESERVICE HINTSWhen Gas Pressure Is Too Low• pilot will not stay lit• burners will have delayed ignition• heater will not produce specified heat• propane/LP gas supply may be lowTECHNICAL SERVICEYou may have further questions about installation, operation, ortroubleshooting. If so, contact DESA International’s TechnicalService Department at 1-866-672-6040. When calling, please haveyour model and serial numbers of your heater ready.You can also visit DESA International’s technical services web siteat www.desatech.com.WIRING DIAGRAM(REMOTE-READY MODELS ONLY)Note: For proper operation of optional accessories, the wires fromthe switch to the control valve must be connected exactly as shown:AUTOOFFONThermopileO.D.S. PILOTTHERMOPILEPILOTTHERMOCOUPLEIGNITORVALVETHERMOCOUPLECONNECTIONPILOTOUTTPTH TP THPIEZOSWITCHAUTOOFFONIgnitor CableThermopile WireThermocoupleWireWire Harness24" Thermostat-Controlled 30" Thermostat-ControlledBtu (Variable) 10,000/40,000 10,000/40,000 10,000/40,000 10,000/40,000Type Gas Propane/LP Natural Propane/LP NaturalIgnition Piezo Piezo Piezo PiezoManifold Pressure 7.4" W.C. 3.0" W.C. 7.4" W.C. 3.0" W.C.Inlet Gas Pressure(in. of water)Maximum 14" 10.5" 14" 10.5"Minimum* 11" 5" 11" 5"Shipping Weight 30 lbs. 30 lbs. 34 lbs. 34 lbs.Certified Standards Z21.11.2-2000 Z21.11.2-2000 Z21.11.2-2000 Z21.11.2-2000* For purpose of input adjustment