107070-01FFor more information, visit www.desatech.comFor more information, visit www.desatech.com2727OPTIONAL POSITIONING OFTHERMOSTAT SENSING BULB(Thermostat-Controlled Models Only)FOR MASONRY AND FACTORY-BUILTMETAL FIREPLACEIf your log set cycles to pilot, but the room temperature drops to alower than ideal comfort level before the log set comes back on, youmay want to reposition the thermostat sensing bulb.The thermostat sensing bulb is located near the gas valve assemblyon the mounting bracket. This location allows the thermostat to keepthe room temperature at an ideal comfort level for most fireplaceapplications. For positioning the thermostat sensing bulb else-where, an adhesive-backed mounting clip is available.Tools needed: 1/4" hex driver or socket1. Remove logs. Locate the gas valve assembly and thermostatsensing bulb (see Figure 40).2. With 1/4" hex driver or socket, loosen the thermostat screw.Carefully slide the thermostat sensing bulb out of the retainingclamp (see Figure 42).Note: Do not remove the screw. Make sure you tighten thescrew after removing the thermostat sensing bulb.IMPORTANT: Do not force or bend the thermostat sensingbulb or capillary.3. The thermostat sensing bulb may be located to the lower rightfront side of fireplace. Determine location of sensing bulb, butdo not mount sensing bulb until step 5. If you have a masonryfireplace, see Figure 43 for location. If you have a factory-built metal fireplace, see Figure 44 for location. If your fire-place has glass doors, position sensing bulb directly behinddoor gap on right bottom side (see Figure 45).4. The mounting clip must be a minimum of 3" from bottom offireplace to prevent crimping of capillary. Once you have de-cided on a location, clean the area thoroughly. Remove the pa-per backing from the adhesive on back of mounting clip. Pressthe clip into the new location so that the thermostat sensing bulbwill be positioned vertically with the capillary at the bottom(see Figure 46). Slide the thermostat sensing bulb into the clip.IMPORTANT: Do not crimp capillary.Figure 40 - Location of Gas Valve Assembly and ThermostatSensing BulbFigure 41 - Adhesive-backedMounting ClipFigure 42 - RemovingThermostat Sensing BulbFigure 43 - Locating ThermostatSensing Bulb on MasonryFireplaceFigure 44- Locating ThermostatSensing Bulb on Factory-builtMetal Fireplace